OK it just happened again. Started my python program and it failed with DEFAULT: ow_reconnect.c:TestConnection(52) Failed to reconnect DS9097 bus master!
In a terminal I ran owhttpd -p 3001 -d /dev/ttyS2 --debug and this gave me CONNECT: ow_avahi_link.c:OW_Load_avahi_library(72) No Avahi support. Library libavahi-client couldn't be loaded CONNECT: ow_dnssd.c:OW_Load_dnssd_library(136) Zeroconf/Bonjour is disabled since dnssd library isn't found CALL: ow_parsename.c:FS_ParsedName_anywhere(90) path=[] DEBUG: owlib.c:SetupTemperatureLimits(79) Globals temp limits 0C 100C (for simulated adapters) DEBUG: ow_ds9097U.c:DS2480_initialize_repeatedly(259) Attempt #0 to initialize the DS9097U DEBUG: ow_ds9097U.c:DS2480_big_reset_serial(337) Send the initial reset to the bus master. DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(488) Failed first attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(493) Failed second attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(488) Failed first attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(493) Failed second attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_write(451) wrong response (CD not 44) DEBUG: ow_ds9097U.c:DS2480_big_reset_serial(337) Send the initial reset to the bus master. DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(488) Failed first attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(493) Failed second attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(488) Failed first attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_read(467) wrong response (70 not 00) DEBUG: ow_ds9097U.c:DS2480_set_baud_control(493) Failed second attempt at resetting baud rate of bus master /dev/ttyS2 DEBUG: ow_ds9097U.c:DS2480_configuration_write(451) wrong response (CD not 44) I opened up a browser on http://localhost:3001/ and it says unable to connect. The serial port looks OK mick@mick-desktop:~$ dmesg | grep tty [ 0.000000] console [tty0] enabled [ 0.489257] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 0.489554] 00:09: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 14.681524] 0000:03:07.0: ttyS1 at I/O 0xdf00 (irq = 17) is a 16550A [ 14.681616] 0000:03:07.0: ttyS2 at I/O 0xde00 (irq = 17) is a 16550A mick@mick-desktop:~$ I then rebooted and it all works fine! Any idea what could cause this problem? Thanks Mick ------------------------------------------------------------------------------ Special Offer-- Download ArcSight Logger for FREE (a $49 USD value)! Finally, a world-class log management solution at an even better price-free! Download using promo code Free_Logger_4_Dev2Dev. Offer expires February 28th, so secure your free ArcSight Logger TODAY! http://p.sf.net/sfu/arcsight-sfd2d _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers