Hi Paul, On 03/02/2011 08:49 AM, Paul Alfille wrote:
> That's interesting that the humidity effects only one sensor, not the whole > bus. Yes, I also thought it was pretty interesting. Furthermore, I don't know if this makes this more interesting, or if it has any relevance, but this sensor that had the 85 degrees problem is not the last one on the bus -- the bus has 12 DS18B20s, and the one that had problems is #8. The 7 sensors before, and the 4 sensors after, didn't have any problems during the duration of the event. > The HobbyBoards people used a special coating for their PCBs that > seems effective. > > What is the design of your sensor -- what does the PCB do? Oh, the PCB is just a convenience so I don't have to mess up with wires (including soldering a sensor to the end of a cat5 cable) and so things look a bit more tidy and neat. The PCB is 100% passive; just a DS18B20 sensor and a female RJ-45 jack soldered to the PCB (in most cases there isn't even an RJ-45 since I just solder a short cat5 cable that ends in the male RJ-45 that then connects to the RJ-45 jack in the wall). I ordered the PCBs from BatchPCB using the Eagle and Gerber files from: http://www.digitemp.com/dt1a.shtml After reading p4trykx's reply (thanks p4trykx, BTW), though, I am thinking that for this outside location (the actual location is underneath the screened porch in the back of my house; that's why the location is safe from rain) it is better to go without a PCB, and just insulate a cat5 wire with heatshrink and some silicone, similar to what this wine cellar monitoring project uses: http://owfs.org/index.php?page=monitor-a-wine-cellar I made a sensor like the one in that page to monitor water temperature in a fish tank. The sensor got wet due to poor insulation on my part and it is not currently measuring water temperature, but it should be sufficiently protected to measure outside temperature at this location, so I may just repurpose it and build another sensor for the fish tank. That'll probably be the best solution. Cheers, Eloy Paris.- > On Tue, Mar 1, 2011 at 12:54 PM, Eloy Paris<[email protected]> wrote: >> Hi list, >> >> Apologies for the slightly off-topic message but I figured someone here >> may have some suggestions for me on this non-owfs issue I am having... >> >> I have a DS18B20 sensor located outside. It is in a location that is >> safe from water (unless it rains horizontally). My bus master reaches >> this sensor through a cat5 bus that has about 10 more sensors. The >> sensor, its pins, and the small PCB the sensor is soldered to, are all >> exposed (to wind and humidity, but not to direct water). Parasitic >> powered, and Vcc pin is floating (not connected to ground). This setup >> has been pretty stable (no 1-wire errors or bad temperature readouts in >> 6 months of operation). >> >> Last night there was heavy rain and thunderstorms in the area and for a >> period of about two hours I was getting the dreaded 85 degrees C from >> this sensor. All other sensors were fine during this time and did not >> report 85 degrees. The problem fixed itself a bit after rain and >> thunderstorms passed. >> >> I think it is humidity what causes the 85 degrees C readout since we've >> had a few warm and humid days/nights recently (but no rain) and I've >> gotten a few 85 degrees C readouts here and there from the same sensor. >> But nothing like last night when I consistently got 85 degrees C >> readouts for about two hours. >> >> Next time this happens I plan on grounding Vcc to see if that helps, but >> I also wanted to ask the list for theories on what could be causing >> these 85 degrees C readouts when it is humid (or when there are >> thunderstorms in the area). >> >> If grounding Vcc does not help I think my next step should be to protect >> from the elements the sensor, its pins, and the small PCB. Any ideas on >> how to accomplish this; is there some coating I can spray on the >> sensor's pins and on the PCB that will protect them from humidity? >> >> Thanks in advance for any suggestions. >> >> Cheers, >> >> Eloy Paris.- >> ------------------------------------------------------------------------------ Free Software Download: Index, Search & Analyze Logs and other IT data in Real-Time with Splunk. Collect, index and harness all the fast moving IT data generated by your applications, servers and devices whether physical, virtual or in the cloud. Deliver compliance at lower cost and gain new business insights. http://p.sf.net/sfu/splunk-dev2dev _______________________________________________ Owfs-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/owfs-developers