On Tue, Mar 1, 2011 at 6:54 PM, Eloy Paris <[email protected]> wrote:

I have a DS18B20 sensor located outside. It is in a location that is
> safe from water (unless it rains horizontally). My bus master reaches
> this sensor through a cat5 bus that has about 10 more sensors. The
> sensor, its pins, and the small PCB the sensor is soldered to, are all
> exposed (to wind and humidity, but not to direct water).


...

If grounding Vcc does not help I think my next step should be to protect

> from the elements the sensor, its pins, and the small PCB. Any ideas on
> how to accomplish this; is there some coating I can spray on the
> sensor's pins and on the PCB that will protect them from humidity?
>

In my experience the 85 degrees issue can be caused by a number of issues.

- bad timing on the bus (especially when using bitbanging)
- reading high temperatures on a parasite powered bus
- very long busses with lots of sensors (picking up noise)
- capacitive issues on the wiring (often related to using shielded wiring)

Since your busmaster (and hence timing) didn't change and you're most likely
not reading 80+ degrees C outside, I think the suspect here is the wiring.
If water entered your CAT5 cabel it's electrical properties will change and
the capacity of the cable will change. Make sure that everything outside is
totally isolated from water.

- Jan
------------------------------------------------------------------------------
Free Software Download: Index, Search & Analyze Logs and other IT data in 
Real-Time with Splunk. Collect, index and harness all the fast moving IT data 
generated by your applications, servers and devices whether physical, virtual
or in the cloud. Deliver compliance at lower cost and gain new business 
insights. http://p.sf.net/sfu/splunk-dev2dev 
_______________________________________________
Owfs-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to