Hi Masaaki, I will hold off testing on my end until you have a chance to test with nightly binaries. Please let us know how it goes.
Regards, -berk On Tue, Mar 17, 2015 at 8:09 AM, <[email protected]> wrote: > You could test it with the nighly builds from the dashboard. That way you > don't have to compile anything. > > You can find more information here: > http://www.paraview.org/Wiki/ParaView_Nightly_Binaries > > -Armin > > > > On Tue Mar 17 12:27:27 2015 GMT+0200, Masaaki SHOJIMA wrote: > > Hi, Michael, > > > > I found a web-page regarding the CGNS reader, in which you are making > > important comments. > > http://comments.gmane.org/gmane.comp.science.paraview.user/23957 > > > > I have to wait for the next version, is it right? > > > > Thanks > > > > Masaaki > > > > 2015-03-17 16:02 GMT+09:00 Mickael Philit <[email protected]>: > > > > > Hello, > > > > > > sorry to intrude, > > > I think the problem may come from the CGNS loader of ParaView. > > > When using the CGNS plugin from ParaView development version, you get > the > > > same picture as Ensight. > > > My two cents > > > > > > Mickael > > > > > > > > > On 17/03/2015 05:04, Masaaki SHOJIMA wrote: > > > > > > Hi Berk, > > > > > > I appreciate your kindness > > > > > > Here, I attaches the data. > > > Compare Gradient.pdf (252KB) > > > > > > A calculated field by SC/Tetra solver is uploaded in Dropbox. > (Calc.zip) > > > Please download the data. It contains FLD format for SC/Tetra post and > > > CGNS format for Ensight and Paraview. > > > https://www.dropbox.com/s/5fpeu1qwhyzjn5u/Calc.zip?dl=0 > > > > > > (1) I calculated the flow and the pressure in a simple cylinder for a > test > > > ( diameter 0.005m, length 0.01m). Plug flow at inlet with 0.03 m/s. > > > > > > (2) Data were transfered to Ensight and Paraview in CGNS format. > > > > > > (3) Pressure was mapped on the surface and compared between SC/Tetra > post, > > > Ensight and Paraview. All application provided same results. > > > > > > (4) Gradient (pressure) was calculated in each post and z-component of > > > Gradient (pressure) was visualized with same colored contour. Only > paraview > > > provided a different image because the computed gradients in paraview > had > > > half values compared to SC/Tetra post and Ensight. > > > > > > (5) Gradient (velocity-X) was also calculated in each post and the > > > X-component of Grad (velocity-X) was visualized. Same results as shown > in 4. > > > > > > > > > Thanks a lot. > > > > > > Masaaki > > > > > > > > > > > > > > > _______________________________________________ > > > Powered by www.kitware.com > > > > > > Visit other Kitware open-source projects at > http://www.kitware.com/opensource/opensource.html > > > > > > Please keep messages on-topic and check the ParaView Wiki at: > http://paraview.org/Wiki/ParaView > > > > > > Search the list archives at: http://markmail.org/search/?q=ParaView > > > > > > Follow this link to subscribe/unsubscribe: > http://public.kitware.com/mailman/listinfo/paraview > > > > > > > > > > > > > -- > Sent from my Jolla > _______________________________________________ > Powered by www.kitware.com > > Visit other Kitware open-source projects at > http://www.kitware.com/opensource/opensource.html > > Please keep messages on-topic and check the ParaView Wiki at: > http://paraview.org/Wiki/ParaView > > Search the list archives at: http://markmail.org/search/?q=ParaView > > Follow this link to subscribe/unsubscribe: > http://public.kitware.com/mailman/listinfo/paraview >
_______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Search the list archives at: http://markmail.org/search/?q=ParaView Follow this link to subscribe/unsubscribe: http://public.kitware.com/mailman/listinfo/paraview