That should read: "n5 = sample rate" instead of "n3 = sample rate" It's for Linux, of course. Don't know how to handle this in Windows or OSX.
Ingo > -----Original Message----- > From: Pd-list [mailto:[email protected]] On Behalf Of Ingo > Sent: Sunday, April 09, 2017 10:53 AM > To: 'Christof Ressi'; 'mario buoninfante' > Cc: [email protected] > Subject: Re: [PD] refresh MIDI device list on run > > You need to refresh the midi dialog by banging this: > > [; pd midi-dialog 1 2 3 4 1 2 3 4 4 4( > > first 4 = input device numbering (might be different than "1 2 3 4", e.g. "2 > 0 > 0 0") > next 4 = output device numbering (might be different than "1 2 3 4") > #9 = number of input devices (1-4) > #10 = number of output devices (1-4) > > Same thing for audio-dialog: > > [; pd audio-dialog n1 n1 n1 n1 n2 n2 n2 n2 n3 n3 n3 n3 n4 n4 n4 n4 n5 n6( > > n1 = inputs device numbers > n2 = number of input channels per device > n3 = outputs device numbers > n4 = number of output channels per device > n3 = sample rate > n6 = delay in milliseconds > > Making an automatic refresh is a bit difficult. > > I did it by monitoring the dev folder (or actually I created a subfolder for > my > known devices and I'm monitoring changes with > > [hcs/folder_list /dev/"mididevice-subfolder-name"/*] every 3 seconds. > > When a change is detected it bangs [; pd midi-dialog 1 2 3 4 1 2 3 4 4 4( > So all of my "known" devices (by udev names) are mounted automatically. > For unknown devices I need to execute a [bang] on [; pd midi-dialog 1 2 3 4 > 1 > 2 3 > 4 4 4( > > Ingo > > > > -----Original Message----- > > From: Pd-list [mailto:[email protected]] On Behalf Of > > Christof Ressi > > Sent: Sunday, April 09, 2017 10:11 AM > > To: mario buoninfante > > Cc: [email protected] > > Subject: Re: [PD] refresh MIDI device list on run > > > > Never worked for me (for audio devices neither), I always had to > > restart Pd > > :- > > (. Also with audio devices. > > > > > > > > Gesendet: Sonntag, 09. April 2017 um 09:51 Uhr Von: "mario buoninfante" > > <[email protected]> An: [email protected] Betreff: [PD] > > refresh MIDI device list on run > > > > Hi all, > > does anyone know if it's possible to "refresh" the MIDI device list > > while Pd is running? i.e. you plug a new device on run. > > Cheers, > > Mario > > _______________________________________________ Pd- > [email protected] > > mailing list UNSUBSCRIBE and account-management -> > > https://lists.puredata.info/listinfo/pd-list > > > > _______________________________________________ > > [email protected] mailing list > > UNSUBSCRIBE and account-management -> > > https://lists.puredata.info/listinfo/pd-list > > > > _______________________________________________ > [email protected] mailing list > UNSUBSCRIBE and account-management -> > https://lists.puredata.info/listinfo/pd-list _______________________________________________ [email protected] mailing list UNSUBSCRIBE and account-management -> https://lists.puredata.info/listinfo/pd-list