Patrick,

  The manual power setting is relative to the flash maximum output
  power.
  You cannot set multiple 500FTZ to different power levels in TTL
  operation, only in manual. To achieve that you need to use the more
  recent 360FGZ (with cameras that support the P-TTL mode) and dial
  specific compensation on each unit.
  Your example (main light with lower fill light) can only be achieved
  with 500FTZ in the so called contrast control mode where output is
  ditributed as 1/3 for the fill flash and 2/3 for the main flash.

  Servus,  Alin
  
PG> When one sets the AF500FTZ to manual mode and sets the power to 1/2,
PG> 1/4, 1/8 power etc... 
PG> The power level is relative to what :
PG>     a) the 500FTZ's maximum power ?
PG>     b) the metered reading taken by the camera ?

PG> If using multiple flashes e.g. 2 x AF500FTZs can you set the power level
PG> of one flash relative to the other and still maintain TTL operation
PG> using the 5p sync cord system.  E.g

PG> Use a main light with a fill light at 1 or 2 stops below the main light.

PG> If i did not explain myself clearly pls say say so and i'll rephrase

PG> Tnx

PG> Patrick

Reply via email to