Many thanks for the reply. I had been doing global changes already just that it's rather a nuisance. During the design process I update the PCB a number of times so have to change the designator height each time as well.
Regards Fred ----- Original Message ----- From: "Brad Velander" <[EMAIL PROTECTED]> To: "Protel EDA Discussion List" <[email protected]> Subject: RE:[PEDA] Protel99SE Default designator text height Date: Tue, 24 May 2005 14:55:25 -0700 > > Fred, > Yes, that and other similar issues are a bit of a pain in P99SE. > However fixing the issue is less than 10 seconds work after they > are all added, simply use global change to change all the 60mil > Ref. Des. heights to 50mil. Leave it until you have entered all or > a significant number of parts, even wait until the final steps of > the design and then change their height and locate them. > > You will notice similar problems with Via tenting. Again it only > takes seconds to fix once you have a number of vias in the design. > > Sincerely, > Brad Velander > Senior PCB Designer > Northern Airborne Technology > 1925 Kirschner Rd., > Kelowna, BC, V1Y 4N7. > tel (250) 763-2329 ext. 225 > fax (250) 762-3374 > > > -----Original Message----- > From: Fred Bloggs [mailto:[EMAIL PROTECTED] > Sent: May 24, 2005 2:15 AM > To: [email protected] > Subject: [SPAM] - [PEDA] Protel99SE Default designator text height - > Email found in subject > > > When I update the PCB from schematic the designator text height is > set to 60mils. I have changed the default in preferences so it's > 50 and indeed if I manually place a component the designator text > height is 50mils. However when I update the PCB from schematic, a > new component has a designator text height of 60mils. Where am I > going wrong? > > Yours very frustrated! > > Fred > > > ____________________________________________________________ > You are subscribed to the PEDA discussion forum > > To Post messages: > mailto:[email protected] > > Unsubscribe and Other Options: > http://techservinc.com/mailman/listinfo/peda_techservinc.com > > Browse or Search Old Archives (2001-2004): > http://www.mail-archive.com/[email protected] > > Browse or Search Current Archives (2004-Current): > http://www.mail-archive.com/[email protected] -- _______________________________________________ NEW! Lycos Dating Search. The only place to search multiple dating sites at once. http://datingsearch.lycos.com ____________________________________________________________ You are subscribed to the PEDA discussion forum To Post messages: mailto:[email protected] Unsubscribe and Other Options: http://techservinc.com/mailman/listinfo/peda_techservinc.com Browse or Search Old Archives (2001-2004): http://www.mail-archive.com/[email protected] Browse or Search Current Archives (2004-Current): http://www.mail-archive.com/[email protected]