On Fri, May 6, 2011 at 1:54 PM, John Mathew <[email protected]> wrote:

> Medfield platform uses MSIC power meter. This patch enables
> power estimates to be displayed for Medfield.
>
John,
The power supply system is generic, and does not depend on medfield.
I think it would be better to not call it "msic.c", but rather call it
power_supply.c
and we could also not hardcode "pmic-battery", but rather walk the
power_supply sources, and check for one that is of battery type or has
status discharging.

Pierre