Palo Verde provides the following response: Current procedural guidance requires that if the in-progress reviews should be used to evaluate / adjust dose estimates including electronic dosimeter setpoints (up or down) to ensure that they remain accurate and challenging. These modifications are required to be included in outage ALARA reports a s lessons learned. Palo Verde is also refining this process by modifying the RWP procedure to examine the efficacy of electronic dosimeter setpoints if current radiological survey data differs from expected (historical conditions) and by developing metrics to identify, track, and trend specific events to identify areas for improvement in radiological work planning such as quantifying the overall frequency of accumulative and rate alarms, identifying unique tasks or work areas that are experiencing these alarms, and adjusting RWP alarm setpoints as needed.
Seth. ********************************************************************** Seth J. Kanter, CHP, RPT Sr. Health Physicist Palo Verde Nuclear Generating Station Mail Sta. 7397 5801 S. Wintersburg Rd. Tonopah, AZ 85354 Phone (623) 393-3130 Fax (623) 393-2487 Unless otherwise noted, all opinions are my own Liviu Librescu ********************************************************************** From: [email protected] [mailto:[email protected]] On Behalf Of Thompson, David A Sent: Wednesday, September 29, 2010 4:25 AM To: ([email protected]) Subject: Powernet: RWP Setpoint Changes Duke currently establishes RWP dose and dose rate setpoints based on historical data for outages, with various tasks under the RWP having setpoints commensurate with the area work is to be performed. Does anybody have a process where they would adjust these established setpoints once the unit is off-line, and initial surveys are completed, dependent on conditions identified? David A. Thompson, CHP Manager Nuclear Fleet RP/Chemistry [email protected] 704-382-6773 Email Firewall made the following annotations --------------------------------------------------------------------- --- NOTICE --- This message is for the designated recipient only and may contain confidential, privileged or proprietary information. If you have received it in error, please notify the sender immediately and delete the original and any copy or printout. Unintended recipients are prohibited from making any other use of this e-mail. Although we have taken reasonable precautions to ensure no viruses are present in this e-mail, we accept no liability for any loss or damage arising from the use of this e-mail or attachments, or for any delay or errors or omissions in the contents which result from e-mail transmission. ---------------------------------------------------------------------