Cook responds with RP Manager (aka RP Superintendent) approves recovery
plan
IF the source cannot be secured in the radiographic exposure device, THEN:
a. The Radiographer shall notify all personnel involved in the
radiography.
b. RP shall immediately control access to the area. Posting shall
be implemented per: 12-THP-6010O-RPP-418, Radiological Posting.
C. The RP Supervisor shall immediately notify the Shift Manager
and the RP Superintendent.
d. The Contract Manager shall notify Work Control Center,
Security, and Fire Protection.
e. RP provide radiological support and oversight during recovery
efforts.
f. The RP Superintendent or designee shall approve implementation
of the Radiographer's emergency procedures (i.e., recovery efforts inside
the HRA boundary), or alternative plan.
g. Implement the Radiographer's emergency procedures or
alternative plan approved by the RP Superintendent or designee.
h. RP and the Radiographer or Radiographer's Assistant shall
maintain constant surveillance of the affected area.
Dave Raye
RP Support General Supervisor
Cook Nuclear Plant
Bridgman, MI 49106
269-466-2803
[email protected]
Sent by: [email protected]
06/08/2011 03:21 PM
Please respond to
[email protected]
To
[email protected]
cc
Subject
Powernet: Radiography Question
One more powernet question for today, thanks!
For an emergency situation such as a stuck radiography source. Do you
obtain the Shift Manager's approval of the recovery plan? At SONGS, only
the RP Manager and the Radiographer's RSO approve the recovery plan.
Sandra Sewell
Health Physics Technical Support
San Onofre Nuclear Generating Station
(949) 368-9111
PAX 89-111 ----------------------------------- Powernet - a service of the
Health Physics Society Power Reactor Section Powernet archives at
http://www.mail-archive.com/[email protected]/ Reply to: [email protected]
If Questions, contact Mike Russell, CHP at [email protected]
----------------------------------------------------------------
This e-mail message and all attachments transmitted with it from the
Nuclear Generation Group of American Electric Power are for the sole
use of the intended recipient(s) and may contain confidential and
privileged information. Any unauthorized review, use, disclosure or
distribution is prohibited. If you are not the intended recipient, please
contact the sender by reply e-mail and destroy all copies of the original
message.