Fort Calhoun Station general dose rates on refueling bridge during fuel movement is 2 to 3 mr/hr The last time we put lead on the bridge was during failed fuel time period.
From: [email protected] [mailto:[email protected]] On Behalf Of [email protected] Sent: Thursday, August 11, 2011 9:44 PM To: [email protected] Subject: Powernet: Couple Quick Benchmark Question San Onofre would like to know: 1) What are the general area dose rates on your refuel machine during core off-load/on-load? 2) Do you install any shielding on your refuel machine (deck or handrail) ? If so, what type (lead/tungsten, blanket/sheet etc.)? Thank you, Roger Scott Sherman Technical Specialist Scientist Health Physics Planning Department San Onofre Nuclear Generating Station P.O. Box 128, San Clemente, CA 92672 949-368-6423 [email protected] ----------------------------------- Powernet - a service of the Health Physics Society Power Reactor Section Powernet archives at http://www.mail-archive.com/[email protected]/ Reply to: [email protected] If Questions, contact Mike Russell, CHP at [email protected] ---------------------------------------------------------------------- This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, nor acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.