Fermi 2
Loose contamination? EF2 - 8.3 bq / 100 cm2 is our criteria for posting as CA Is all loose contamination found outside of a CCA classified as loose contamination? Are there instances where it would not be counted as a loose event (floor cleaning, large area masslins, etc...)? EF2 - is considered loose, but if less than 8.3 bq / 100 cm2, not posted as CA. If none normally present, may count towards poor practices as contamination was spread outside of posted area Does your station use coveralls as RPPE or civil clothing? Do you use scrubs? Are events on scrubs or other coveralls all counted as PCE's? When would it not be counted? EF2 - Scrubs are used, designated protective overalls are worn over scrubs when entering CA. All personnel CA events are counted. Not sure how you are using coveralls. If coveralls are used specifically for RP PE, at EF2 coveralls would have been removed at exit of CA before personnel monitoring is performed. Benjy Bertossi Fermi2 - RP Supervisor 734-586-4935 [email protected]