At Diablo Canyon, the Control Room (Operations) performs all dose assessment 
until the EOF is activated.

The TSC onsite has computer station capability for dose assessment and our "Rad 
Data Processor" ERO position is trained to perform dose assessment on our 
backup dose assessment (MS Excel spreadsheet based).

Curtis Hansen

Sr. Adv. EP Coordinator - Dose Assessment
Emergency Planning
Plant: 805-545-6619
Pager:  6619
Cell: 805-801-8185

From: Derek Hultquist [mailto:[email protected]]
Sent: Wednesday, December 21, 2016 8:13 AM
To: '[email protected]'; [email protected]
Cc: [email protected]
Subject: [powernet] RE: Quick emergency plan question

This is an EXTERNAL EMAIL. Stop and think before clicking links or opening 
attachments.
*************************************
At Cook, the Control Room (Operations) performs all dose assessment until the 
EOF is activated.

Thanks,

Derek Hultquist
Health Physicist
D. C. Cook NPP
(269) 465-5901 x2088



From: [email protected]<mailto:[email protected]> 
[mailto:[email protected]]
Sent: Wednesday, December 21, 2016 11:07 AM
To: [email protected]<mailto:[email protected]>
Cc: [email protected]<mailto:[email protected]>
Subject: [EXTERNAL] [powernet] Quick emergency plan question

This is an EXTERNAL email. STOP. THINK before you CLICK links or OPEN 
attachments.

________________________________
In the event of a fast-breaking release at your site, which department performs 
your initial dose assessment, before the emergency offsite facility is staffed 
up?

Is it RP, Chemistry, or Operations, etc.?

Thanks!

Heather
[cid:[email protected]][cid:[email protected]]
Heather Jackson, CHP, RRPT| Sr. Health Physicist
*623-393-6076 | 
*[email protected]|<mailto:[email protected]%7C>*623-393-1853 | PVNGS 
Mail Station 7397


--- NOTICE ---

This message is for the designated recipient only and may contain confidential, 
privileged or proprietary information.  If you have received it in error, 
please notify the sender immediately and delete the original and any copy or 
printout.  Unintended recipients are prohibited from making any other use of 
this e-mail.  Although we have taken reasonable precautions to ensure no 
viruses are present in this e-mail, we accept no liability for any loss or 
damage arising from the use of this e-mail or attachments, or for any delay or 
errors or omissions in the contents which result from e-mail transmission.

Reply via email to