Ephraim Schwartz │ Manager │ Health Physics Department
Ontario Power Generation Inc. │ 1549 Victoria Street East,  Whitby, Ontario  
L1N 9E3
Internal: 402 – 3334 │ External: 905.430.2215  ext. 3334 │ Facsimile: 
905.430.8583
Mobile: 416.407.4902

Make every mrem count
From: DUHIG John -NUCLEAR <[email protected]>
Sent: Wednesday, February 22, 2017 7:18 AM
To: SCHWARTZ Ephraim -NUCLEAR
Subject: Powernet question


Hi Ephraim,

Can you ask what other utilities are using for waste bag monitor alarm set 
points through use HPS powernet?

INPO provides an example that is lower than our current alarm set points 
(2.25nCi vs 10nCi).  Based on our MDA, we would be challenged to drop to 
2.25nCi without significantly increasing count times.  I’m interested how (if 
at all) others are achieving this detection limit.

Thanks,

John


INPO 05-008 Rev2 Section 4.f:
f. Unconditional release of clean trash from the radiologically controlled area
Trash is monitored to ensure radioactive material will not be released off 
site. This monitoring may be done in a number of ways. For example, use a 
gamma-sensitive tool or box monitor capable of detecting contamination within 
the bag of trash at a level of 5,000 dpm. Each piece of trash may be surveyed 
with a handheld beta-sensitive frisker, rebagged, followed-by performance of an 
aggregate survey of the material.



-----------------------------------------
THIS MESSAGE IS ONLY INTENDED FOR THE USE OF THE INTENDED RECIPIENT(S) AND MAY 
CONTAIN INFORMATION THAT IS PRIVILEGED, PROPRIETARY AND/OR CONFIDENTIAL. If you 
are not the intended recipient, you are hereby notified that any review, 
retransmission, dissemination, distribution, copying, conversion to hard copy 
or other use of this communication is strictly prohibited. If you are not the 
intended recipient and have received this message in error, please notify me by 
return e-mail and delete this message from your system. Ontario Power 
Generation Inc.

Reply via email to