-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Neil Riley wrote:

> First the good news, for those of you who have been helping with my
> Aurora.
> The KVM switch is now working with my Aurora, After fitting a keyboard
> PS2 to  DIN 
> and PS2 to Serial mouse connector the KVM happily switches between PC
> and Aurora
> and the screen quality is perfect.
> 
> Now for the bad news, The Aurora doesn't appear to fully boot up. I
> will describe best i can 
> what happens when i boot and what messages appear on screen.
> 
> Ok, after switch on i get the usual QL multicoloured screen which
> clears and gives the MINERVA
> logo, shortly followed by the F1/F2 Set Monitor/TV , F3/F4 For Duel
> Screen,  1.93 @ The QView Mega 
> Corporation etc.
> 
> At the top of the screen i get the following:
> 
> TF Services RomDisq V2.14 @ 1997 TT
> Super Gold Card V2.49
> Real Time Clock Failure ( Haven't fitted new Battery in SGC as Yet ! )
> QUBIDE/REBEL Driver v2.01 @1994-98
> Initialising .........  ( the ...... appear one at a time over a few
> seconds)
> FUJITSU MPB3021ATU
> LTN526S
> 
> At this point the PC's keyboard appears to recognise me pressing the F1
> or F2 key although if i wait
> it seems to carry on.
> Although probably not important, If i press the F1 key the screen
> clears, shows the usual window #0,#1 and #2
> where the windows are white / red and black, if i press F2, the screen
> becomes a blue square for a blink of an eye 
> before we have windows #0,#1 and #2 where the windows are black/red and
> black.
> 
> after a couple of seconds, the screen clears again and i get the
> following green on black messages at the top of the screen.
> 
> TF Services RomDisq V2.14 @ 1997 TT
> QUBIDE/REBEL Driver v2.01 @1994-98
> Initialising
> 
> Whilst the messages are duplicates of before, the system gets stuck on
> Initialising and continues no further.
> 
> Phil, the previous owner suggested the keyboard driver loaded from the
> RomDisq and prior to fitting the PS2 to DIN convertor 
> suggested the system could be hanging, not able to 'find' the keyboard
> but seeing as F1 and F2 are being picked up oin the 
> initial boot screen I'm no longer certain.
> 
> Appologies for the lengthy nature of this email but I guess the more
> info the better.
> 
> Many Thanks
> Neil.
> 
> p.s. removing the KVM has the exact same results so i've discounted
> this as causing the lockup.
> 
> p.p.s. Before being able to fit the keyboard/mouse i took the RomDisq
> out and booted up, was able to boot up far further, with 
> windows #0/#1 and #2 being shown with plenty of text ( cannot recall
> what all the messages were but there were plenty of Version numbers ! ).
> 
> I haven't performed this since fitting the keyboard mouse so i could
> try that again if need be.
> 
> 
This looks like an issue with the HD boot program.
Boot up off superHermes floppy and investigate win1_boot.
Maybe it is trying to run SMSQ?

Is it running Minerva MKII (with battery)?
If so, remove the small socketed chip, place on alu foil to zap its ram
and replace.  As long as Minnie has a working battery-backed clock the
SGC battery is not essential.  You will need to run the utility to force
the Minerva clock (and miniconfig_bas to reset the MVR values).

Aurora cannot be blamed for this (8-)#

Tony



- --
QBBS (QL fido BBS 2:252/67) +44(0)1442-828255
       [EMAIL PROTECTED]     http://firshman.co.uk
Voice: +44(0)1442-828254 Fax: +44(0)1442-828255 Skype: tonyfirshman
    TF Services, 29 Longfield Road, TRING, Herts, HP23 4DG
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.2 (MingW32)
Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org

iD8DBQFFteHCM3RzOs8+btoRAnzRAJ9BN1fYjNy/agtjzU8f6O7zj46ZJgCfW4f/
1Pigb6w0ItThkg0Vi/A1hqA=
=aKX4
-----END PGP SIGNATURE-----
_______________________________________________
QL-Users Mailing List
http://www.q-v-d.demon.co.uk/smsqe.htm

Reply via email to