On Wed, May 04, 2005 at 07:24:56AM -0700, Robert Spier wrote:
> What is your maximum connection count?

We allow 200 connections with a maximum of 4 per IP.

Turning off MAXCONNIP isn't really realistic either considering how often we
get nailed by virus hosts.

FWIW, we had over 1 million incoming SMTP connections yesterday processed by
qpsmtpd.  I believe one day last week we had about 300k on an 'average' day;
once we did some tweaks to ease the load on clamd, qpsmtpd was handling the
load albeit with the frequent SEGVs.  -- justin