Hi again group,

Ok..I'm now able to adjust T207 to produce -7.6 Vdc at E209, so the effort has been rewarded.

I wish I could say for certain what the cause for the prior low output has been, but I did not find a faulty component including coil resistances, a bad cable or connector, or anything else. Even C227, the .047uF PIO cap tested fine after I replaced it with a film cap.

I replaced C268 and C327 with Mica caps, an 82K resistor and thoroughly checked wiring and switches.

The one thing I did find was that C275 had been replaced with a .0033uF cap rather than the .033 called for. I'm not exactly sure what effect that might have had, but there was a reason for the published corrections.

I'm going to do some contact cleaning and a little lubrication before I re-intall the deck and move closer to the finish...

73...Jordan VE6ZT