My Lucent (Livingston) PortMasters are capable of using a feature named 
"call-check". With this feature, the PM sends an authentication request 
before it accepts an incoming call. The request specifies the 
phone-number from which the call is coming as the user name. Radius has 
the opportunity to reject the call immediately and return a busy signal 
to the caller. Alternatively, the call can be accepted and the caller 
then put through the normal authentication process.

I have over 100 PortMasters world-wide and I'd like to use this feature 
on most of them. However, if I enable the feature and Radiator is not 
set-up to process the requests, the PMs will default to rejecting the 
call and all callers will get busies. So I believe it is imperative to 
get Radiator properly configured first.

According to Lucent, the proper way to respond to most call-check 
requests is with a single users file entry like this at the very end of 
the file.

  DEFAULT  Service-Type = Call-Check

Because this line contains no reply items, the PM treats the response 
as an indication that the call should be accepted but the caller put 
through the normal authentication process.

If I add this line to my users file, my Radiator log file (2.13.1, at 
trace level 3) starts recording lines like the following.

  Wed Jul 21 17:37:10 1999: INFO: Access rejected for joeblow:
  Check item Service-Type value 'Call-Check' does not match
  'Framed-User' in request

"joeblow" is a valid user with a proper entry earlier in the users 
file. These messages continue at a high rate until I remove the DEFAULT 
line from the users file.

Suggestions?
-- 
        Dave Close              Quik Internet
        +1 949 548 2171         Costa Mesa California
        [EMAIL PROTECTED]         http://www.quik.com/


===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.