Hello Todd -
On Mon, 15 Nov 1999, Todd Knaus wrote:
> Dear Fellow Platypus & Radiator Users,
>
> Sorry for the cross post but I am really at wits end and not sure what
> to do.
>
> Here's the deal, We have 2 RADIUS servers running, a primary
> and a secondary. Our Primary RADIUS server is Radiator running on an NT
> server along side Platypus. Our secondary Radius server is Livingston
> Radius version 2.1 running on a BSDI 3.1 Unix box.
>
> Our terminal or RAS servers are all Livingston/Lucent PM3's running code
> 3.8c2. We have 3 in the main office that support 28.8 through ISDN
> connections and all have PRI lines from Ameritech. The 4th is at a
> remote office but has a channalized T1 (from Sprint) so it only supports
> connection up to 56k.
>
> With the above setup we are seeing ALOT of customers not being
> disconnected prorperly.....on all 4 systems. For example, A customer
> will call in, stay connected for 30 minutes and then terminate the call.
> The Portmaster however is still showing them connected. Unless we go
> out and manually reset the lines the "ghost users" will stay connected
> it seems indefinatly. As a test, I left one user connected I knew had
> terminated the session because I phoned them. After 2 days they were
> still connected! The only we thing we have not tested is if a session
> is still active and the user dials back in, what happens.....we are not
> sure.
>
> This had been going on for several days since we installed Radiator.
> Since it was getting to hard to track we switched the Radius Servers so
> that the Unix box was now the primary and Radiator was the secondary.
> We rebooted all the PM's to make sure there were no "ghost sessions"
> and waited to see what would happend. After running for 2 days
> everyone was being disconnected properly so to make sure I was not
> insane I switched back, making Radiator the Primary and Unix the
> secondary and we are back to the same problem. We have been running
> with Radiator as the primary since Thursday. It is Sunday morning and
> we have several users that have been connected 1 to 2 days. This is not
> a common occurence for most of these people as they are low end users
> averaging 25 to 30 hours a month. Yes, we have our abusers but these
> "ghost sessions" seem to be happening to almost all of our customers
>
> I think I can rule out the phone lines since it is happening on all the
> lines and as stated, 3 are from Ameritech and 1 is from Sprint.
>
> I am not sure if the problem is with my Radiator cfg file or something
> in Platypus. If anyone has any hints or ideas I will love to hear them.
> Also, can someone share the .cfg file with me ? It is possible I am
> missing something in there......right now I am using <AuthBy Emerald>
> and have the RadiusNT SQL hooks in Platypus.
>
> What I don't undersand is why or how are these sessions are staying
> active ? If a user on the other end disconnects the call I would think
> the Portmasters wouldn't care about Radiator or Platypus and it would
> just terminate the session and clear the line.
>
Could you capture the packet sequences from both the Radiator sessions and the
Livingston Radius sessions (using something like tcpdump or the NT packet
analyser)? It would be very helpful to see what is different between the two.
It may very well be that there is some additional attribute being returned by
the Livingston that needs to be added to the Radiator configuration.
thanks
Hugh
--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald,
Platypus, Freeside, TACACS+, PAM, external, etc etc on Unix, Win95/8,
NT, Rhapsody
===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with