Stuart,
>Every day I have to open a ball valve I have on the
>top of the reactor to release the extra co2 pressure
>and then the reactor fills up with water once again
>till the next day it starts all over!
You are letting too much carbon dioxide into the reactor. Reduce your CO2
flow rate. Another option is to reduce the pressure coming from the CO2
regulator.
A way to minimise the problem if it occurs every now and then, place your
water exit location at the top of the unit so that any excess CO2 can leave
with the water exiting the unit, rather than build up in the reactor unit.
Catch ya,
DBW | The Caretaker, OZ REEF Marine Park
Melbourne | http://ozreef.org/
Australia | [EMAIL PROTECTED]
--------------------------------------------------------------------------
When the only tool you own is a hammer, every problem begins to resemble a nail.