According to my Micor manual, the TLD5953A PA Board is installed
in the TLD1693E Contunuous Duty Power Amplifier on the 150.8 - 162
MHz frequency range.
Is this what you are looking for?
Neil - WA6KLA
wn1b8 wrote:
>
> I recently picked up a Micor Compa-Station exciter/PA. I know its
> for 132-174 MHz. and I believe it to be a 100 watt PA deck, but I
> can't seem to find what the duty cycle is. The PA board part number
> is TLD5953A1093R. It has the 14 1/2" long Micor fins across the top
> of the module. The module, with the fins, is 6" high.
>
> I know this isn't the 100% duty cycle configuration, but can it be
> run at 100% if it has constant forced air cooling across the fins?
> Also, the board appears to be the same for the 100 watt 100%
> configuration. Is it possible to simply replant this board in the
> larger chassis/heat sink? Assuming for a moment that I could find a
> dead one.
>
> Any help and/or advice will be greatly appreciated.
>
> Scott Madison, WN1B
>
>
> Yahoo! Groups Links
>
>
>
>