Kerry

I use Dow Corning # 111 Non Dielectric Grease but do not recommend above 
high band VHF also works
on Low band   . Just a matter a matter of your preference some don't like or 
recommend it but have used 30 years . Have gone back to sites 10 years later 
opened up fittings looked brand new inside.
there is "STUF" Above High Band VHF.

                                        Dale      N8SAC

----- Original Message ----- 
From: "Joe" <[EMAIL PROTECTED]>
To: <[email protected]>
Sent: Sunday, November 13, 2005 6:08 PM
Subject: Re: [Repeater-Builder] repeater antenna connection


> Yes, here is a product called STUF.  Look at:
> http://www.wavehunter.com/
> and look for informaton for "Stuf Dielectric WaterProofing Filler"
> My company tried this product on an 800MHZ system with terrible results. 
> Poor return loss readings, loose connectors after time, were some of the 
> problems.  Your results may vary.
>
> 73, Joe, K1ike
>
>> >     Is there anything that can be applied to the
>> > inside of an antenna connection to prevent corrosion
>> > and oxidation?....Kerry - WA2NAN -
>> > [EMAIL PROTECTED]






 