Kerry
I use Dow Corning # 111 Non Dielectric Grease but do not recommend above
high band VHF also works
on Low band . Just a matter a matter of your preference some don't like or
recommend it but have used 30 years . Have gone back to sites 10 years later
opened up fittings looked brand new inside.
there is "STUF" Above High Band VHF.
Dale N8SAC
----- Original Message -----
From: "Joe" <[EMAIL PROTECTED]>
To: <[email protected]>
Sent: Sunday, November 13, 2005 6:08 PM
Subject: Re: [Repeater-Builder] repeater antenna connection
> Yes, here is a product called STUF. Look at:
> http://www.wavehunter.com/
> and look for informaton for "Stuf Dielectric WaterProofing Filler"
> My company tried this product on an 800MHZ system with terrible results.
> Poor return loss readings, loose connectors after time, were some of the
> problems. Your results may vary.
>
> 73, Joe, K1ike
>
>> > Is there anything that can be applied to the
>> > inside of an antenna connection to prevent corrosion
>> > and oxidation?....Kerry - WA2NAN -
>> > [EMAIL PROTECTED]