Wonder if anyone has had this problem and know what the problem is.  I am 
working on a GE Exec II repeater (converted mobile) which has no Comb no.  I 
any case the issue is that if I move around the cable feeding it with a 
generator I was seeing a change in the recieve.  
     I went directly to the RCA jack, and then found that just making 
connection with the center pin, I have about 10 to 20db stronger recieved 
signal than when I push it all the way in making the ground connection.  
     This is a mobile and the RF deck is no. is 19D417075G14 rev A covered by 
LBI30032E. This shows a option of either non floating ground or floating ground 
input.  This one is a non floating ground one.  Might have been changed but I 
have know knowledge of its history. 
     The RCA jack center pin connects directly with a wire thru a hole to the 
first helical and I have looked and can see no connection issues and measures a 
short with an ohm meter.  I even reheated the solder joints and no change.  
Anythoughts would be appreciated. 

Randy 

Reply via email to