--- In [email protected], "skipp025" <skipp...@...> wrote:
>
> When you remove the PL Module from the back plane you lose 
> the reverse burst CTCSS (PL) function.  What advantage would 
> you have/get from using a TS-32 tone board? 
> 
> You can download the external controller on an MSR-2000 
> repeater information from the www.radiowrench.com/sonic web 
> page and it will tell you how to make the repeater operate 
> carrier squelch. 
> 
> First off... there are two jumpers on the Squelch Gate Module
> that need to be moved over to carrier squelch or the TS-32 
> needs to source the proper signals to the SQM so it will 
> operate. 
> 
> s. 
> 
> > "Howard Klino" <hklino@> wrote:
> >
> > I have gotten a MSR2000 repeater working with the the "PL" card in it.I do 
> > not want to use this card as I have installed a TS-32 board.  When I remove 
> > the "PL" card, both transmit and receive are disabled.  What do I jumper to 
> > stop this from happening.  It blocks me from using the meter jack for the 
> > transmitter.
> > 
> > Howard   K2IMO


> >  First let me say that the unit was not originally a repeater.  It was a 
> > base station on EMS freqs.  It did not have a squelch card in it.  I did 
> > another conversion to it that required a TS-32 or TS-64 so I put it in.  I 
> > wanred both incode and decod capabilities. It has a CAT controller mounted 
> > where the second receiver should be. Everything works great and has for 
> > over a year.

Now back to the original question.  In order to use the metering socket for 
tune-up of the transmitter, you have to trmove the "PL" card which is mounted 
just below the transmitter.  When doing this, you lose transmit capabilities 
and receive.   Once you plug in the test meter, you can no longer put the "PL" 
card back in.  What I need to know is what lumpers do I have to put in inorder 
to be able to transmit and receive with the "PL" card removed.  I have no 
documentation on the boards. 

Howard   K2IMO
>


Reply via email to