Sorry if I've been late in posting. First, the antenna and hard line is ok. 
We've tested that part out and its working. We think ( I ) that we got zapped 
through a unused phone line which is mounted behind the repeater rack.
Yes, we have tested the can's using both a IRL (?sp) and a General Dynamics 
service monitor. They were taken apart and cleaned and retuned. Everything 
indicated they were functioning normally. Till we put them back in service. I 
don't know if they were tested with a dummy load. The technicians made many 
trips to the site: the technicians worked for the company that we rent the site 
from. We replaced all of the connectors and only found one that had scorched 
indications on it, but that was all.
I asked if any of you knew how to find out if a can was operational, because 
all the test equipment that was used  indicated they were ok. We finally found 
a workable solution. We added a fifth can, tuned to the transmit freq. That 
stoped the crackling noise. 
Now we're going to replace the can's, and go with a 6 can configuration. this 
is what was reconmended by the technician.

Rich K8JX