At 3/3/2010 14:19, you wrote:
>skipp025 wrote:
> > The more famous surplus commercial radio 224 MHz conversions
> > replace the PA with a Hybrid RF Amplifier Module... wonder if
> > they also include SWR Protection?


>In the case of the GE MASTR II, power control is done with a simple pot,
>and all SWR protection, leveling, etc. is bypassed/eliminated - at least
>with this interface board.  Maybe someone has hacked the MASTR II PA to
>allow for the incorporation of its protection in a 220 conversion - but
>I have never saw it if it has been done.
>
>Kevin Custer

Most RF power modules sold today are spec'd to withstand 20:1 VSWR.  That's 
a lot of reflected power, probably more than what you'd ever see if your 
repeater antenna opened or shorted due to the feedline & duplexer losses.

Bob NO6B