There is an RSS software solution ("bitbang") to get rid of the alarms.
Connect the RIB to the operating MSF.
>From the main menu hit ALT-F5. A command line bar will appear telling you to 
>enter an IPCB command. Enter the following: (WITHOUT the " " quotes)

              "/1e1607160800FF" 

it is CASE sensitive. This sets the FWD/REV settings to zero and FF (infinity)
I've done it many times, and it works just fine!


--- On Sun, 8/29/10, jimmylpowell <[email protected]> wrote:

From: jimmylpowell <[email protected]>
Subject: [Repeater-Builder] Msf5000 Low Power alarms
To: [email protected]
Date: Sunday, August 29, 2010, 12:36 PM







 



  


    
      
      
      I originally posted this on the MSF5000 board but got no response. I

thought I would broaden my search.



Does anyone know a way to get a non trunking MSF with out an internal

power

sensor to stop giving the 7 beeps? I have tried going back to a default

codeplug

and starting from scratch. This did not work. It seems that once the bit

is

set it won't go away. I'm sure that it happened when someone went into

the

screen to adjust the alarms. I know this is a common problem and they

tell you

not to do it.



I have the alarms disabled over the air, but it annoys me on the local

audio. I

would like to enable the over the air alarms, but I can't until I can

clear this

one.



My MSF has version 4.07 SSCB and 5.04 TTRC.



Maybe there's some bit banging that can be done.



Jimmy, K5JCT





    
     

    
    


 



  






      