On Fri, 07 Feb 2014 09:42:45 +0900
Yuichi Ito <[email protected]> wrote:

> some switches return the instruction list of flow_mod messages in the 
> different order.
> 
> for example, when a flow entry was installed with the instructions as:
> 
>   [
>     OFPInstructionMeter(meter_id=1),
>     OFPInstructionActions(actions=[OFPActionOutput(port=2)])
>   ]
> 
> the flow_stats message may return the flow entry with the instructions as:
> 
>   [
>     OFPInstructionActions(actions=[OFPActionOutput(port=2)]),
>     OFPInstructionMeter(meter_id=1)
>   ]
> 
> this patch makes tester.py ignore the order different.

Hmm, the order matters from the perspective of OF spec?

------------------------------------------------------------------------------