#5107: incorrect trailing digits for continued fraction
--------------------------------+-------------------------------------------
   Reporter:  robertwb          |       Owner:  somebody    
       Type:  defect            |      Status:  needs_review
   Priority:  critical          |   Milestone:  sage-4.3.1  
  Component:  basic arithmetic  |    Keywords:              
Work_issues:                    |      Author:              
   Upstream:  N/A               |    Reviewer:              
     Merged:                    |  
--------------------------------+-------------------------------------------

Comment(by was):

 +1 to the referee patch.
 Robert: You expected continued_fraction(symbolic) would be some cool lazy
 infinite continued fraction object, since the function
 "continued_fraction" didn't have any documentation.   It would be nice to
 have that capability, but nobody has written it.    At least now
 continued_fraction clearly documents what it does.

 Perhaps the only thing that would easily make you happy right now would be
 to require the prec option if the input is symbolic?  That way in the
 future when somebody writes "continued_fraction(pi)", then it will work as
 you want...  Thoughts?

-- 
Ticket URL: <http://trac.sagemath.org/sage_trac/ticket/5107#comment:7>