Matthias Bruestle writes:
> On Tue, Jan 29, 2002 at 09:14:09PM +0100, Klaus Peter Gungl wrote:
> > Please don't make such broad global statements "Gemplus OP application 
> > loader does not work with IBM cards".
> 
> Ok, I will correct this: The Gemplus OP application loader I had did not
> work with the IBM cards I had.[1] It is not that uncommon with smart cards,
> that there are at least minimal differences, e.g. an application could to
> a select requesting an FMP and the card according to ISO/IEC 7816-4 does
> not support it.

I think the reason is that the Gemplus application loader derivates the on-card
keys for authenticating and downloading code from the keys you specify in their
off-card environment. In case of the IBM card, this additional key-derivation leads 
to an invalid key presented to the card by the GemPlus off-card environment.

I do not know whether GemPlus officially publishes the key-derivation scheme
they use in their application loader. 

Regards,
Marcus



***************************************************************