Re: [ccp4bb] Automated refinement convergence
Thank you all for the replies. My goal was to learn about practical ways to achieve convergence during refinement even if the supplied model for the density will never be able to model the density adequately. I may experiment with refmac's ability to terminate refinement when a criteria has been met such as delta_Rfreehttps://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/
[ccp4bb] Automated refinement convergence
Hi, I am wondering if authors of refinement programs would like to consider putting on their users wish list the ability of refinement programs to automatically terminate once the refinement has reached convergence. Various refinement metrics such as R factors, CC or RMS values typically will reach a plateau once the refinement of a macromolecular structure with X-ray or EM-data has converged and further macro-cycles of refinement will no longer improve the structure. The default number of macro-cycles in programs such as Phenix-refine and Refmac are probably sensible for most cases but in some cases it would be nice if the programs automatically extended the number of macro-cycles as needed (or decreased the number). The user can of course examine log files from refinement themselves and decide whether to continue refinement. But since starting a new session of refinement appears to always create an initial fluctuation in the refinement metrics before they align with the values of the last macro-cycles in the previous refinement session, the user is compelled to do at least, say 3 or more macrocycles in addition to whatever may be needed for reaching convergence. I guess it would therefore be more efficient if this was implemented directly in the refinement programs and presented as an option for the user to choose. There could be cases where alternate conformations of a structure will repeatedly be oscillating in and out of density thus causing the refinement metrics also to oscillate. Hopefully such cases could be covered by gauging the level of fluctuations of the refinement metrics and terminate the refinement accordingly. Many thanks, Robert To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/
[ccp4bb] skewness in a good EM map?
Hi, In crystallography one of the features of a good map is that the histogram of map values has skewness. Does this also apply to EM maps? Whereas X-ray maps depicts the electron density EM maps depicts the electrostatic potential as I understand it. Any pointers about skewness or not in EM maps is greatly appreciated. thanks, Rob To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/
[ccp4bb] IUCR template for bibliography in Microsoft Word
Hi To those using Microsoft Word without a citation manager for writing papers to IUCR journals. The (IUCr) IUCr Journals Microsoft Word template <https://journals.iucr.org/services/wordstyle.html> to be installed on a PC prior to writing a paper for an IUCR journal does not contain a bibliography style. Of the built in bibliography styles in Word the closest ones are probably "Havard Anglia" or "APA". Both of these truncate the list of authors in a publication after a maximum number has been reached or they have various fields (like date or year) rearranged compared to the style format of bibliographies in IUCR papers. The workaround I have found is using tools from GitHub - codingo/BibWord: Microsoft Word and Bibliography Styles extender. <https://github.com/codingo/BibWord> Installing these on my PC the closest matching bibliography style to IUCR I found was "Harvard Exeter" Amendments to the maximum number of authors was needed as well as getting rid of title of cited article in the bibliography. This was far easier than trying to hack through any of the built in bibliography styles of Microsoft Word. For those interested the attached bibliography style is named MyIUCR.XSL, It should go into the folder C:\Users\\AppData\Roaming\Microsoft\Bibliography\Style . Once there, Microsoft word will make it available from the "Style" drop-down list on the "References" tab. Hope this helps someone, Robert -- Robert Oeffner, Ph.D. Research Associate, The Read Group Department of Haematology, Cambridge Institute for Medical Research University of Cambridge Cambridge Biomedical Campus The Keith Peters Building Hills Road Cambridge CB2 0XY www.cimr.cam.ac.uk/investigators/read/index.html tel: +44(0)1223 763234 To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/ <>
Re: [ccp4bb] Generating symmetry mates using python
b but it doesn't >> quite solve the problem. >>> I also tried opening PyMol through the command and generating >> symmetry mates this way. It worked on a few files but failed quite >> quickly (segmentation fault) and was also very slow. >>> Can anyone suggest a useful solution, preferably clear to use >> and/or well documented? Or even have a python script/code they can >> share for this? >>> >>> Best regards, >>> Orly >>> >>> -- >>> >>> Orly Avraham, Ph.D. >>> Postdoctoral fellow >>> The lab of Prof. Oded Livnah >>> and the lab of Prof. Ora Schueler-Furman >>> The Hebrew University of Jerusalem >>> Israel >>> >>> >>> >>> >>> To unsubscribe from the CCP4BB list, click the following link: >>> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB=1 >>> >>> >>> >>> >>> To unsubscribe from the CCP4BB list, click the following link: >>> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB=1 >> >> > >> >> To unsubscribe from the CCP4BB list, click the following link: >> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB=1 >> >> -- >> >> Orly Avraham, Ph.D. >> Postdoctoral fellow >> The lab of Prof. Oded Livnah >> and the lab of Prof. Ora Schueler-Furman >> The Hebrew University of Jerusalem >> Israel >> >> - >> >> To unsubscribe from the CCP4BB list, click the following link: >> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB=1 > > -- > > Orly Avraham, Ph.D. > Postdoctoral fellow > The lab of Prof. Oded Livnah > and the lab of Prof. Ora Schueler-Furman > The Hebrew University of Jerusalem > Israel -- Orly Avraham, Ph.D. Postdoctoral fellow The lab of Prof. Oded Livnah and the lab of Prof. Ora Schueler-Furman The Hebrew University of Jerusalem Israel To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB=1 -- Robert Oeffner, Ph.D. Research Associate, The Read Group Department of Haematology, Cambridge Institute for Medical Research University of Cambridge Cambridge Biomedical Campus The Keith Peters Building Hills Road Cambridge CB2 0XY www.cimr.cam.ac.uk/investigators/read/index.html tel: +44(0)1223 763234 To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB=1
Re: [ccp4bb] Structural biology software that does not run on Windows or gives important Windows-specific problems
We build Phenix on all three platforms, i.e. Windows, Linux and MacOSX. Microsoft provides great C/C++compilers for free on Windows. One minor issue though is that since our software uses Python 2.7 binary compatibility with the python2.7 installer requires that the rest of Phenix is built with the older VS2008 compiler. That edition doesn't support the latest bells and whistles of esoteric C++ language features but this is not a showstopper. Rob Subject: Re: Structural biology software that does not run on Windows or gives important Windows-specific problems From: Patrick LollDate: Fri, 14 Oct 2016 12:31:54 -0400 How about the ability to compile code? Are there decent compilers readily available for Windows? I like being able to write & compile the occasional fortran program {hic sunt dinosaurs}, and it’s easy to do this on a unix-based platform like OSX. If your reasoned arguments fail, I have found that many institutions' information technology administrators are easily intimidated by a few random references to unix (Rsync! Grep! Bash!). Such words seem to function as charms that keep evil spirits (i.e. IT administrators) at bay. > On 14 Oct 2016, at 11:14 AM, Mark J van Raaij wrote: > > Dear All, > > our institution requires me to provide a reasoning not to buy a Windows > computer (I want to buy a new MacOSX system), so I am looking for software > that does not run or is limited on Windows. > > Not available: > (Auto)SHARP > ARPWARP > > Available on Windows but with significant limitations > Phenix (no MR-Rosetta, no parallelization) > CCP4 (limitations on file-names) > > Please correct me if pertinent and provide additional examples if possible. > > Gratefully yours, > > Mark > > Mark J van Raaij > Dpto de Estructura de Macromoleculas > Centro Nacional de Biotecnologia - CSIC > calle Darwin 3 > E-28049 Madrid, Spain > tel. (+34) 91 585 4616 > http://wwwuser.cnb.csic.es/~mjvanraaij
Re: [ccp4bb] Installation of CCP4 under Windows 7
Hi, I have encountered this problem with CCP4 6.2.0 as well as for the past few years. Whenever I run the CCP4 installer for all users on my Windows Vista PC as administrator it only creates desktop icons and startup menu item for the administrator account, not for other users. It appears that the CCP4 desktop icon shortcut is put in C:\Users\Administrator\Desktop and the start menu CCP4 folder is put in C:\Users\Administrator\AppData\Roaming\Microsoft\Windows\Start Menu\Programs\CCP4-Packages-6.2.0. Both of these paths are incorrect as they are invisible when logging in as another user. I'm not sure where the CCP4 desktop icon shortcut should go but placing the startup folder in C:\ProgramData\Microsoft\Windows\Start Menu\Programs makes it accessible to other users. On a separate note, it also appears that there is a bug in the ActiveTCL installer which is recommended to be installed on Vista platforms. It only makes file associations with tcl files for the user who installed this program. Consequently when double clicking the CCP4 icon as a different user than administrator windows prompts the user asking what program the file should be opened with. Again this can be overcome by making the wish.exe program from the ActiveTcl folder the default program to use. Regards, Robert Oeffner, Ph.D. Research Associate, Read group Department of Haematology, University of Cambridge Cambridge Institute of Medical Research Wellcome Trust / MRC Building, Hills Road, Cambridge, CB2 0XY www-structmed.cimr.cam.ac.uk, tel:01223763234
[ccp4bb] strange error in superpose
Hi all, When I use the superpose program for SSM aligning these two structures in the following command line: superpose 3BT1.pdb -s B 1OC0.pdb -s B superposed.pdb The screen output reads: PDB file 3BT1.pdb has been read in. ... 312 atoms selected using CID 'B' PDB file 1OC0.pdb has been read in. ... 289 atoms selected using CID 'B' Transformed coordinates will be written to file superposed.pdb *** empty graph for 1OC0.pdb. If I try loading the same structures (or just use the PDB codes) in the SSM server http://www.ebi.ac.uk/msd-srv/ssm/cgi-bin/ssmserver it seems to work just fine. Does anybody know how to avoid this error? Many thanks, Rob