Re: Large SVCDUMPS
In 351fdc6ace57d14b94beb5529e85df8e91b04b7...@exchmail1.courts.wa.gov, on 10/31/2011 at 10:04 AM, Longnecker, Dennis dennis.longnec...@courts.wa.gov said: Can someone point me to the right place to find the documentation on how to create large SVCDUMP datasets? SMS. I don't know whether SDUMP supports EAV, but old fashioned extended is good enough for mod 9. -- Shmuel (Seymour J.) Metz, SysProg and JOAT ISO position; see http://patriot.net/~shmuel/resume/brief.html We don't care. We don't have to care, we're Congress. (S877: The Shut up and Eat Your spam act of 2003) -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: Large SVCDUMPS
Thanks all.teach me for not keeping up with JCL parameters and knowing DSNTYPE=LARGE was actually a JCL option! Putting // DSNTYPE=LARGE, In my allocation did the trick! Dennis -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Longnecker, Dennis Sent: Monday, October 31, 2011 10:04 AM To: IBM-MAIN@bama.ua.edu Subject: Large SVCDUMPS Can someone point me to the right place to find the documentation on how to create large SVCDUMP datasets? I need to create a large dump dataset so I can take a console dump of DB2. I keep getting partial dumps. I see in the messages the maximum size of a dataset is 65,535 tracks which for a 3390 is 4369 cylinders. In the z/OS MVS diagnosis: Tools and Service Aids manual they say IBM Recommends using extended format sequential data sets as dump data sets for SVC dumps..and they can hold 128 gigabytes.But the manual doesn't give any clues on how to create them. IBM APAR II06335 talks about the subject also: Note: With DFSMS120 and Dynamic Dump Allocation, multi-volume EFDS format datasets can be created for your SVCDUMP. but doesn't give any clues on how to create such a beast either. I've tried created the SYS1.DUMP dataset on a MOD 9 with the contig option, but it stops at the 65,535 tracks. Any pointers appreciated. Dennis -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: Large SVCDUMPS
On 10/31/11 13:04, Longnecker, Dennis wrote: Can someone point me to the right place to find the documentation on how to create large SVCDUMP datasets? I need to create a large dump dataset so I can take a console dump of DB2. I keep getting partial dumps. I see in the messages the maximum size of a dataset is 65,535 tracks which for a 3390 is 4369 cylinders. In the z/OS MVS diagnosis: Tools and Service Aids manual they say IBM Recommends using extended format sequential data sets as dump data sets for SVC dumps..and they can hold 128 gigabytes. But the manual doesn't give any clues on how to create them. IBM APAR II06335 talks about the subject also: Note: With DFSMS120 and Dynamic Dump Allocation, multi-volume EFDS format datasets can be created for your SVCDUMP. but doesn't give any clues on how to create such a beast either. I've tried created the SYS1.DUMP dataset on a MOD 9 with the contig option, but it stops at the 65,535 tracks. Any pointers appreciated. Dennis You specify whether a dataset is allocated in extended format in it's data class. I don't know off hand if SVCDUMP processing supports DSNTYPE=LARGE, but if so that would be another option. -- Mark Jacobs Time Customer Service Tampa, FL One of life's greatest mysteries is how the boy who wasn't good enough to marry your daughter can be the father of the smartest grandchild in the world. Yiddish Proverb -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: Large SVCDUMPS
Dennis, We set up a SMS pool and do dynamic dumps to that pool. This command is what controls the size allowed for the dump. CHNGDUMP SET,SDUMP,MAXSPACE=6000M You can display by doing D D,S This is an example of the commands to start the SMS MGMT part. DUMPDS NAME=SYS0.DUMPSYSNAME..DYYMMDD..SSEQ DUMPDS ADD,SMS=(MGMT=MCDUMP,STOR=SCDUMP,DATA=DCDUMP) DUMPDS ALLOC=ACTIVE Hope it helps. John Eatherly -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: Large SVCDUMPS
On Mon, 31 Oct 2011 10:04:01 -0700, Longnecker, Dennis wrote: Can someone point me to the right place to find the documentation on how to create large SVCDUMP datasets? I need to create a large dump dataset so I can take a console dump of DB2. I keep getting partial dumps. I see in the messages the maximum size of a dataset is 65,535 tracks which for a 3390 is 4369 cylinders. In the z/OS MVS diagnosis: Tools and Service Aids manual they say IBM Recommends using extended format sequential data sets as dump data sets for SVC dumps..and they can hold 128 gigabytes.But the manual doesn't give any clues on how to create them. http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/DGT2D490/3.6.10.2 DSNTYPE=LARGE is allowed for SVC Dump (z/OS 1.7 or later) http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/IEA2V1B0/2.1.3 http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/DGT2D490/3.6.11 Norbert Friemel -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: Large SVCDUMPS
Sir, Try DSNTYPE=LARGE. Kind Regards Jim Thomas 617-233-4130 (mobile) 636-294-1014(res) j...@thethomasresidence.us (Email) -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On Behalf Of Norbert Friemel Sent: Monday, October 31, 2011 12:29 PM To: IBM-MAIN@bama.ua.edu Subject: Re: Large SVCDUMPS On Mon, 31 Oct 2011 10:04:01 -0700, Longnecker, Dennis wrote: Can someone point me to the right place to find the documentation on how to create large SVCDUMP datasets? I need to create a large dump dataset so I can take a console dump of DB2. I keep getting partial dumps. I see in the messages the maximum size of a dataset is 65,535 tracks which for a 3390 is 4369 cylinders. In the z/OS MVS diagnosis: Tools and Service Aids manual they say IBM Recommends using extended format sequential data sets as dump data sets for SVC dumps..and they can hold 128 gigabytes.But the manual doesn't give any clues on how to create them. http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/DGT2D490/3.6.10.2 DSNTYPE=LARGE is allowed for SVC Dump (z/OS 1.7 or later) http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/IEA2V1B0/2.1.3 http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/DGT2D490/3.6.11 Norbert Friemel -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html - No virus found in this message. Checked by AVG - www.avg.com Version: 2012.0.1834 / Virus Database: 2092/4586 - Release Date: 10/31/11 -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: Large SVCDUMPS
I take it you've seen this already as well. from: II14016 Another message to be aware of is MSGIEA043I MAXSPACE REACHED. This indicates a PARTIAL dump. At minimum, set DB2 using system to a reasonable level, in MVS Commands see these commands: DISPLAY : D D,OPTIONS CHNGDUMP : CD SET,SDUMP,TYPE=XMEME,MAXSPACE=8000M MAXSPACE=8000M minimum for DB2 z/OS V8 later Note: See II06471 : DUMPSRV uses AUX storage for dumping, you may need to add an extra PAGE dataset when dumping DBM1. Note: Allocate a hi-capacity device like a 3390 mod9 for dumps. **use ACS routines for size *** Note: With DFSMS120 and Dynamic Dump Allocation, multi-volume EFDS format datasets can be created for your SVCDUMP. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: Large SVCDUMPS
IBM Mainframe Discussion List IBM-MAIN@bama.ua.edu On 10/31/11 13:04, Longnecker, Dennis wrote: Can someone point me to the right place to find the documentation on how to create large SVCDUMP datasets? I need to create a large dump dataset so I can take a console dump of DB2. I keep getting partial dumps. I see in the messages the maximum size of a dataset is 65,535 tracks which for a 3390 is 4369 cylinders. In the z/OS MVS diagnosis: Tools and Service Aids manual they say IBM Recommends using extended format sequential data sets as dump data sets for SVC dumps..and they can hold 128 gigabytes.But the manual doesn't give any clues on how to create them. IBM APAR II06335 talks about the subject also: Note: With DFSMS120 and Dynamic Dump Allocation, multi-volume EFDS format datasets can be created for your SVCDUMP. but doesn't give any clues on how to create such a beast either. I've tried created the SYS1.DUMP dataset on a MOD 9 with the contig option, but it stops at the 65,535 tracks. Any pointers appreciated. Dennis You specify whether a dataset is allocated in extended format in it's data class. I don't know off hand if SVCDUMP processing supports DSNTYPE=LARGE, but if so that would be another option. -- Mark Jacobs Time Customer Service Tampa, FL In z/OS 1.13, SDUMP specifies the DSNTYPE=LARGE text unit on its SVC 99 parameters if the dump data set needs to be larger than 64K tracks. Prior to z/OS 1.13, you can use Extended Format Sequential data sets for large dumps. Such data sets must be SMS managed, and you would make the request for Extended Format in your SMS ACS routines. Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html