Yup, the sync pulse is present as you can see there in my screenshot.
On 1/3/2017 9:07 PM, Forrest Christian (List Account) wrote:
No, it just means that if you sync the 450i via the timing port, the
GPS status screen won't show up correctly. The sync itself works fine.
On Tue, Jan 3, 2017
No, it just means that if you sync the 450i via the timing port, the GPS
status screen won't show up correctly. The sync itself works fine.
On Tue, Jan 3, 2017 at 7:45 PM, Jerry Head
wrote:
> Um, does this mean that when I hang my first 450i 900Mhz I cannot sync it
>
Um, does this mean that when I hang my first 450i 900Mhz I cannot sync
it my existing FSK gear?
On 1/3/2017 3:40 PM, Forrest Christian (List Account) wrote:
Cambium has a bug in serial receive in the 450i. I know it's on
their to be fixed list.
On Jan 3, 2017 12:45 PM, "George Skorup"
L-Com/KP presents some interesting potential
On Tue, Jan 3, 2017 at 5:11 PM, Chuck McCown wrote:
> Must be these guys:
> http://www.infiniteelectronics.com/
>
> *From:* Timothy Steele
> *Sent:* Tuesday, January 03, 2017 4:03 PM
> *To:* af@afmug.com
> *Subject:* [AFMUG] Infinite
Must be these guys:
http://www.infiniteelectronics.com/
From: Timothy Steele
Sent: Tuesday, January 03, 2017 4:03 PM
To: af@afmug.com
Subject: [AFMUG] Infinite Electronics Acquires KP Performance Antennas
Have not heard of Infinite Electronics before. Not finding much on the
google...
There is an Infinite Electronics – Taiwan Linkedin say they make vacuum
cleaners.
From: Timothy Steele
Sent: Tuesday, January 03, 2017 4:03 PM
To: af@afmug.com
Subject: [AFMUG] Infinite Electronics Acquires KP
Interesting, that company also owns Pasternack, Fairview and L-Com. KP has
been doing very well (and is a nice Canadian success story), I hope this
allows them to continue.
On Jan 3, 2017 5:03 PM, "Timothy Steele" wrote:
>
http://www.antennasonline.com/main/news/infinite-electronics-acquires-kp-performance-antennas/
Yeah that's right. I remember being in the same situation. Cambium has a
back-door password. Call them and have them remote in. Setup a keylogger
first. Send it to me after the call ; )
On Tue, Jan 3, 2017 at 4:36 PM, Jon Langeler
wrote:
> Radio is on the desk. Reset
Radio is on the desk. Reset plug only defaulted the IP
Jon Langeler
Michwave Technologies, Inc.
> On Jan 3, 2017, at 5:25 PM, Eric Muehleisen wrote:
>
> Climb up with reset plug or call into Cambium with RDP or teamviewer session.
> They no longer support 320 platform,
On 1/3/17 13:24, Chuck McCown wrote:
Interesting, motor driven knife switch. I guess it is fast enough to
not arc too much.
I wouldn't trust it over a contactor or static switch under load.
Unloaded I guess it's cheap. But that's me, clearly I'm not a smartmeter
designer.
~Seth
Climb up with reset plug or call into Cambium with RDP or teamviewer
session. They no longer support 320 platform, so they may tell you to fly a
kite.
On Tue, Jan 3, 2017 at 4:20 PM, Jon Langeler
wrote:
> What do you do when the AP IP address defaults but not the
What do you do when the AP IP address defaults but not the login password?
Jon Langeler
Michwave Technologies, Inc.
Cambium has a bug in serial receive in the 450i. I know it's on their to
be fixed list.
On Jan 3, 2017 12:45 PM, "George Skorup" wrote:
> I just got some of the SyncBox Junior Aux port version in and I connected
> it up to a 900 450i AP running 15.0.2. Turned on UGPS power,
Interesting, motor driven knife switch. I guess it is fast enough to not
arc too much.
-Original Message-
From: Ken Hohhof
Sent: Tuesday, January 03, 2017 1:53 PM
To: af@afmug.com
Subject: Re: [AFMUG] Smartmeter Security question
https://www.youtube.com/watch?v=yQdeLQqaStA
oh yeah, and time of day billing. carrots and sticks, etc.
From: Af on behalf of Ken Hohhof
Sent: Tuesday, January 3, 2017 1:59 PM
To: af@afmug.com
Subject: Re: [AFMUG] Smartmeter Security question
Ssssh! You’re
https://www.youtube.com/watch?v=yQdeLQqaStA
-Original Message-
From: Af [mailto:af-boun...@afmug.com] On Behalf Of Seth Mattinen
Sent: Tuesday, January 3, 2017 2:37 PM
To: af@afmug.com
Subject: Re: [AFMUG] Smartmeter Security question
On 1/3/17 12:26, Ken Hohhof wrote:
> Why can it not
First time I've tried this. I have a site with two 5750APs. They are
quite obviously overloading the receiver on the ePMP GPS AP. Put numbers
in the co-lo spreadsheet, timing checks out. Running the ePMP in the 5.4
band. Still works for shit.
This is a very compact micro-pop, so we have SMs
On 1/3/17 12:26, Ken Hohhof wrote:
Why can it not be an electromechanical relay, maybe a latching type?
http://www.johnsonelectric.com/en/features/residential-electricity-meter-disconnect-relay
I would expect at 200 amps either a contactor or SCR because of the risk
of contact welding,
SSRs for AC normally have a triac for switching which is a bidirectional SCR.
In any event, it has pretty low on resistance but you still have to heat sink
them for any decent amount of current.
Perhaps the smart meter has a way to get the heat out of the switch. I would
think it would not be
The receiver info section at the bottom is part of the serial data. I'm
not sure why it would see that and nothing else. But that is Motorola
binary format. And I remember Forrest saying something about the 450i
not liking that. It'd be nice to have a jumper or something on the
SyncBox to
Why can it not be an electromechanical relay, maybe a latching type?
http://www.johnsonelectric.com/en/features/residential-electricity-meter-disconnect-relay
-Original Message-
From: Af [mailto:af-boun...@afmug.com] On Behalf Of Seth Mattinen
Sent: Tuesday, January 3, 2017 2:09 PM
To:
He also said they're required to take pictures of the empty socket
before they put the new meter on. The fires that have made the news are
because of bent/loose contacts in the meter base.
On 1/3/2017 2:11 PM, Bill Prince wrote:
SSRs (Solid State Relays). These can be pretty robust in my
On 1/3/17 11:12, Nate Burke wrote:
I just happened to be at a property today where they were install a new
smartmeter. The Tech confirmed that they do have the ability to cut to
the power to the house from the meter.
Must have SCRs in it then.
~Seth
Ssssh! You're supposed to pretend it's about making the grid more
resilient and offering futuristic features to the ratepayers. You can't
just blurt out the real reasons like that.
Now they're going to have to bring in a PR team to clean up your mess, maybe
tell us it was swamp gas and
Is it possible the sync pulse is working, but the serial data is not?
On Tuesday, January 3, 2017 11:46 AM, George Skorup
wrote:
I just got some of the SyncBox Junior Aux port version in and I connected it
up to a 900 450i AP running 15.0.2. Turned on UGPS power,
I just got some of the SyncBox Junior Aux port version in and I
connected it up to a 900 450i AP running 15.0.2. Turned on UGPS power,
box powers up. Pretty cool. But still no GPS data. Turn off GPS message
checksum and it still doesn't work, the receiver info section just gets
all corrupt.
It's cute to see PMP450 catching up with ePMP.
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Tue, Jan 3, 2017 at 2:26 PM, Jeff Broadwick - Lists
wrote:
> 40 Mbps key with the latest firmware...for the 20 Meg price. I have
The 450d is better with a dish there is a little RF that falls off the back
of a reflector dish with the 450d being inner feed you get rid of that
issue resulting in much better performance even if you swap a dish for a
450d and signal stays the same you will still see better link caps from the
I thought that was the point? Remote on/off and shitcan all their meter
readers
From: Af on behalf of Nate Burke
Sent: Tuesday, January 3, 2017 1:12 PM
To: af@afmug.com
Subject: Re: [AFMUG] Smartmeter Security
40 Mbps key with the latest firmware...for the 20 Meg price. I have a number
of Cambium customer's that have settled on the 450d as their primary SM of
choice.
Jeff Broadwick
ConVergence Technologies, Inc.
312-205-2519 Office
574-220-7826 Cell
jbroadw...@converge-tech.com
> On Jan 3, 2017, at
The 450d is pretty much the same gain as a standard SM + 27RD style
reflector. Maybe 1dB better.
The 450d board is exactly the same as a standard SM. Integrated patch
and all. The only difference is in software. It's locked to 24 or 25dBi
total antenna system gain.
The new wideband 5GHz SM
I've heard some reports that there's a 1-3 dbi difference between one and
the other. I think it's the same in the grand scheme of things.
The biggest thing is the 450d comes with a better license.
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
License is tied to the serial of the disk.
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Tue, Jan 3, 2017 at 1:35 PM, Adam Moffett wrote:
> That's what I was hoping.
>
> -- Original Message --
> From: "Josh
I just happened to be at a property today where they were install a new
smartmeter. The Tech confirmed that they do have the ability to cut to
the power to the house from the meter.
On 1/3/2017 9:42 AM, Ken Hohhof wrote:
Good news: would probably trip the breaker
Bad news: probably not
I have not bought PMP450 SMs in some time.. we had a stock of PMP450 SMs w/
RCL-2 dishes.. We estimated an overall system gain of 25 dbi.
The PMP450d spec sheet indicates 25 dbi as well.
Has anyone compared the PMP450+RCL-2 with a PMP450d and can quickly comment
on gain differences.
Any idea who's waveguide transition they are using? Dual Pol N to Circular
I presume, would have to be.
-Original Message-
From: Daniel White
Sent: Tuesday, January 03, 2017 11:36 AM
To: af@afmug.com
Subject: Re: [AFMUG] Question Regarding 11ghz Links.
I'm way late to this... but
I'm way late to this... but that is an all indoor installation most likely.
They are using waveguide to the antenna (note the fixed losses on each side of
the link).
3dB loss per side is the equivalent of losing an antenna size.
I'd also assume this link was engineered to 99.%
That's what I was hoping.
-- Original Message --
From: "Josh Luthman"
To: "af@afmug.com"
Sent: 1/3/2017 10:26:39 AM
Subject: Re: [AFMUG] RouterOS License question
As long as the "disk" didn't change your license will persist.
Josh Luthman
The VLAN method does work. You can also do a full duplex link utilizing two
sets of radios. This has been around for quite some time. But that also
assumes you have radios of the same relative capacity.
Justin Wilson
j...@mtin.net
---
http://www.mtin.net Owner/CEO
xISP Solutions- Consulting
What Eric said.
Except, I believe you said the two links were of unequal capacity. OSPF
can't natively load balance unequal paths. If you set them to equal
cost, you'll actually get 2x the capacity of the smaller link, and the
larger link will be underutilized. There was a trick somebody
Just trying to pump us up.
From: Ken Hohhof
Sent: Tuesday, January 03, 2017 9:46 AM
To: af@afmug.com
Subject: Re: [AFMUG] OT - new Apprentice catchphrase(s)
When Austria sends its people, they’re not sending their best. They’re
bringing barbells. They’re bringing steroids. They’re
When Austria sends its people, they’re not sending their best. They’re
bringing barbells. They’re bringing steroids. They’re bodybuilders.
From: Af [mailto:af-boun...@afmug.com] On Behalf Of Chuck McCown
Sent: Tuesday, January 3, 2017 10:38 AM
To: af@afmug.com
Subject: Re: [AFMUG] OT -
You won’t be back
From: Ken Hohhof
Sent: Tuesday, January 03, 2017 9:08 AM
To: af@afmug.com
Subject: [AFMUG] OT - new Apprentice catchphrase(s)
You’re terminated, now get to the choppa!
Is it too late to choose Arnold for President and Donald for Celebrity
Apprentice? Seriously. I mean
You're terminated, now get to the choppa!
Is it too late to choose Arnold for President and Donald for Celebrity
Apprentice? Seriously. I mean it would probably be bad for Apprentice, but
priorities?
Good news: would probably trip the breaker
Bad news: probably not fast enough
More bad news: that kind of voltage would probably arc right across the
opening breaker contacts
Maybe there's a fuse for that. Like the ones up on poles that you reset with a
hot stick.
-Original
As long as the "disk" didn't change your license will persist.
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Tue, Jan 3, 2017 at 8:03 AM, Trey Scarborough wrote:
> On 1/3/2017 5:32 AM, Adam Moffett wrote:
>
>> I just backed up
I doubt it. Much more energy involved when a primary gets into a secondary.
Not short duration impulses like lightning.
-Original Message-
From: Nate Burke
Sent: Monday, January 02, 2017 6:08 PM
To: af@afmug.com
Subject: Re: [AFMUG] Smartmeter Security question
Would one of those
I have seen this around for a while. Not understanding why they use PV to
extract the energy at 20% conversion rate where thermal extraction will be
close to 100%. Smacks of quakery when “dark matter” is invoked.
From: Rory Conaway
Sent: Tuesday, January 03, 2017 7:04 AM
To: af@afmug.com
Don’t let the interns near it.
OK, never mind, they’re easily replaced. And no issues disposing of the body,
that machine will probably vaporize the evidence, just make sure you have an
exhaust fan.
From: Af [mailto:af-boun...@afmug.com] On Behalf Of Chuck McCown
Sent: Tuesday,
Not quite, 4000 volts at 150 amps with a specific waveform on the pulse.
From: Adam Moffett
Sent: Tuesday, January 03, 2017 4:42 AM
To: af@afmug.com
Subject: Re: [AFMUG] Smartmeter Security question
I don't know if you've seen a show called "White Rabbit Project".
Episode 1 features Tory
https://www.youtube.com/watch?v=siHCRp7TpoU
There is a little bit of controversy here but they are going to field test this
year and release product in 2018. This could be a game changer.
Rory Conaway * Triad Wireless * CEO
4226 S. 37th Street * Phoenix * AZ 85040
602-426-0542
On 1/3/2017 5:32 AM, Adam Moffett wrote:
I just backed up and restored a RouterOS virtual machine.
Is there a way to just confirm that the license is still valid?
Go to System License in winbox or ssh /system license print
I don't know if you've seen a show called "White Rabbit Project".
Episode 1 features Tory Belleci from Mythbusters standing on top of a
Tesla coil wearing a chain mail suit and shooting lightning at stuff
while cackling madly. I suggest something similar for your lightning
impulse
I just backed up and restored a RouterOS virtual machine.
Is there a way to just confirm that the license is still valid?
55 matches
Mail list logo