Re: [AFMUG] crowdsource troubleshooting

2018-05-08 Thread Jacob Turner
The Prism Gen 2 uses "standard" UBNT passive 24v POE. +4,5 -7,8. I've seen netonix switches claiming as much as 12 watts draw from one when running. I wouldn't be surprised if their startup draw may be a bit higher. On Tue, May 8, 2018 at 8:16 AM, wrote: > I need help in

Re: [AFMUG] RF Calibration Failure ADI Catalina R0 chip not supported!

2018-03-23 Thread Jacob Barnard
to RMA replace. Jacob On 3/17/2018 10:21 AM, Andreas Wiatowski wrote: Hi All, I’ve never seen this before…but it looks like I have a broken AP…any way to fix without a climb?? 450 AP 2.4Ghz Cheers, Andreas Wiatowski, CEO Silo Wireless Inc. 1-866-727-4138 x-600 http

Re: [AFMUG] Cambium repair times?

2018-02-22 Thread Jacob Barnard
back to Cambium after all parties have forgotten about them and we get surprised when they show up. -Jacob On 2/20/2018 3:42 PM, Seth Mattinen wrote: How long does it usually take Cambium to repair something? I have an 820S that failed under warranty waiting at their repair facility since

Re: [AFMUG] Lacp/lag Netonix to edgeswitch

2018-01-14 Thread Jacob Turner
This works for me ​ On Fri, Jan 12, 2018 at 1:55 PM, TJ Trout wrote: > Hello , > > Anyone with a working configuration of lacp or lag between a matonix and > edgeswitch that could send over a screenshot of the configuration of each > device if you have it working? > > Having

Re: [AFMUG] Is POE out settings on new powerbox pro different?

2017-07-07 Thread Jacob Turner
Sounds like you may not have enough current to power on all of the prisms. You certainly want a 24v 2.5A power supply at least. You also may have to use the barrel plug instead of POE in to get enough juice. On Thu, Jul 6, 2017 at 9:59 PM, Tim Reichhart < timreichh...@hometowncable.net> wrote:

Re: [AFMUG] Addition to new site.

2017-04-12 Thread Jacob Turner
Gorgeous site! On Wed, Apr 12, 2017 at 7:48 PM, Sam Lambie wrote: > Cambium Medusa. Synced with Packetflux Syncbox 12. Powered with > Syncinjectors by Packetflux. > > Just put it up today so no performance reviews yet. 101 customers coming > from a 450 AP. > > Psyched > >

Re: [AFMUG] ePMP1000 Max PTP length

2017-03-30 Thread Jacob Turner
If you can deal with the slightly higher latency involved in running tdd-ptp mode I'm not sure that there is a hard limit for ePMP. If there is it is likely 60+ miles. Running ePTP mode though there are distance limits of 32 miles for 20Mhz and 15 Miles for 40Mhz. On Thu, Mar 30, 2017 at 10:36

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread Jacob
I believe they have emergency support available at 920-351-1010. Hope that helps! On 8/5/2015 12:10 AM, Josh Luthman wrote: IIRC the only need for DNS is validity to confirm the license for the pretty graphs. Is the BMU up to date? My guess would be something is causing the probe script