Re: [AFMUG] powercode monitoring dead

2015-08-06 Thread Josh Luthman
Thank you Powercode for figuring out a problem on my network? ;) Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 6, 2015 6:28 PM, That One Guy /sarcasm thatoneguyst...@gmail.com wrote: This ended up being a router issue on our side, changed

Re: [AFMUG] powercode monitoring dead

2015-08-06 Thread That One Guy /sarcasm
This ended up being a router issue on our side, changed to a mikrotik and jesus gave me a thumbs up On Wed, Aug 5, 2015 at 11:31 AM, Josh Luthman j...@imaginenetworksllc.com wrote: Probe tab? Really doubt it. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337

Re: [AFMUG] powercode monitoring dead

2015-08-06 Thread That One Guy /sarcasm
Yea, that's for sure, it sucks when it turns out you're THAT customer On Aug 6, 2015 5:31 PM, Josh Luthman j...@imaginenetworksllc.com wrote: Thank you Powercode for figuring out a problem on my network? ;) Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread CBB - Jay Fuller
heya!! look who it is!! - Original Message - From: Jacob To: af@afmug.com Sent: Wednesday, August 05, 2015 12:21 AM Subject: Re: [AFMUG] powercode monitoring dead I believe they have emergency support available at 920-351-1010. Hope that helps! On 8/5/2015 12:10

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread Lewis Bergman
Well, you tried my two go to standards for resolving issues. On Tue, Aug 4, 2015, 11:31 PM That One Guy /sarcasm thatoneguyst...@gmail.com wrote: anybody using powercode and your monitoring is dead? Hopefully its just us and not systemic. Apparently they tested and they can kick probes off on

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread D. Ryan Spott
Did your clock NTP server jump around recently? RRD (the data storage system they are using for graphs) does NOT play well with time changes. Especially ones that go backward. ryan -- D. Ryan Spott | NGC457, llc broadband | telco | colo | communities PO Box 1734 Sultan, WA 98294 425-939-0047

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread Ken Hohhof
Cussed and got drunk? From: Lewis Bergman Sent: Wednesday, August 05, 2015 7:59 AM To: af@afmug.com Subject: Re: [AFMUG] powercode monitoring dead Well, you tried my two go to standards for resolving issues. On Tue, Aug 4, 2015, 11:31 PM That One Guy /sarcasm thatoneguyst...@gmail.com

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread Jason Pond
I had this happen last week when I started upgrading my ubnt network to 5.6.2 it is the result of a bad SNMP probe causing all SNMP to stop functioning from the powercode server. I opened a ticket with powercode and they were able to resolve it. If you made any changes to the monitoring you

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread Josh Luthman
If you have one bad OID for a price none of them work. Removing the bad one makes the probes work instantly. Status check isn't effected by this. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 5, 2015 9:46 AM, Jason Pond

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread That One Guy /sarcasm
We did the 5.6 beta and went through the probe fixes some time back. Haven't added any probes. These situations require liberal applications of swear words and liquor to troubleshoot when home at night and would rather be doing something other than troubleshooting. I have an open ticket with

Re: [AFMUG] powercode monitoring dead

2015-08-05 Thread Josh Luthman
Probe tab? Really doubt it. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 5, 2015 12:24 PM, That One Guy /sarcasm thatoneguyst...@gmail.com wrote: We did the 5.6 beta and went through the probe fixes some time back. Haven't added any

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread Josh Luthman
So probes are what's busted? What about bandwidth collection? Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 5, 2015 12:31 AM, That One Guy /sarcasm thatoneguyst...@gmail.com wrote: anybody using powercode and your monitoring is dead?

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread That One Guy /sarcasm
bandwidth gathering seems to be functional, probes are busted, about every tenth click on reprobe gives me a green box, but it never populates the probes. I rebooted the bmu when the mirror was still present and probes worked during the resync, but failed again at some point, subsequent reboots

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread Josh Luthman
Disk full? Are you monitoring the servers health? Might want to try rebooting the billing server, do a snapshot before though. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 5, 2015 12:45 AM, That One Guy /sarcasm thatoneguyst...@gmail.com

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread That One Guy /sarcasm
Rebooted this evening, pushed the pending update this morning hoping it was that (two revisions pending) no joy.Im at 20gb of 91gb space on the VHD. This is a massive virtual server terabyte raid 10 array powercode datastore 16 core 64gb ram host. Only thing on it is powercode and two lightly hit

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread CBB - Jay Fuller
Monitoring is certainly working heregot an alert about 30 minutes ago about a roughly five-minute outage Sent from my Verizon 4G LTE Smartphone - Reply message - From: That One Guy /sarcasm thatoneguyst...@gmail.com To: af@afmug.com af@afmug.com Subject: [AFMUG] powercode

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread Josh Luthman
IIRC the only need for DNS is validity to confirm the license for the pretty graphs. Is the BMU up to date? My guess would be something is causing the probe script to hang, but it's tough to say. Call in the AM :/ Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337

Re: [AFMUG] powercode monitoring dead

2015-08-04 Thread Jacob
I believe they have emergency support available at 920-351-1010. Hope that helps! On 8/5/2015 12:10 AM, Josh Luthman wrote: IIRC the only need for DNS is validity to confirm the license for the pretty graphs. Is the BMU up to date? My guess would be something is causing the probe script