I believe you are saying what i was saying.
With X number of devices in an autochanger then up to X number of jobs can
run at the same time. Perfect.
On Wednesday, September 27, 2023 at 9:43:42 a.m. UTC-4 Bruno Friedmann
(bruno-at-bareos) wrote:
> Well not really, I've implemented that with
Well not really, I've implemented that with 4 devices in my autochanger
which mean I can run 4 concurrents writes job or 2 read / 2 write for
copy/AI etc.
and I have one storage definition on my director.
Of course that mean I will write 4 distinct volumes at the same time. and
not 4 jobs on a
Thank you to discover one part of the documentation that need to be
rewritten.
Oleg todo is quite right in the term of using bextract with the bsr is the
easiest way to have your catalog back, and maybe also you want to extract
the previous configuration.
Please don't be shy and propose a PR
I saw the autochanger, but that does not allow for parallel jobs correct?
Currently to have parallel jobs you have to define multiple devices and
specify them all in both the sd and dir.
using count simplifies the sd config, but the director with needs each
listed.
On Wednesday, September 27,
the link proposed drive you to the master documentation (see little
droplist at the left bottom) you can choose 22 version
https://docs.bareos.org/bareos-22/Appendix/ReleaseNotes.html
then you have the unreleased (so 22.1.1~pre) changes
Le mercredi 27 septembre 2023 à 09:17:03 UTC+2, Silvio
The trick is to use a virtual autochanger for those kind of device, so only
the changer is declared on the director.
If you want to get inspired, you can have a look at the following PR which
will propose to introduce this
https://github.com/bareos/bareos/pull/1467
Le mardi 26 septembre 2023
Hi,
since last week I can see some connection problems to newer systems.
Some times the backup is working, some times not and the error is a ssl
error.
"bareos-sd JobId 8245: Fatal error: Connect failure:
ERR=error:14094410:SSL routines:ssl3_read_bytes:sslv3 alert handshake
failure"
This