On (2012-10-23 22:06 -0500), Tony Varriale wrote:
None of GBIC will do half duplex IIRC. And, they won't do subrate.
The negotiate is there to appease the other end if it tries.
This is painfully common misconception. So some, even serious SPs tend to
have standard of disabling autonego and
On 10/24/2012 07:23 AM, Saku Ytti wrote:
On (2012-10-23 22:06 -0500), Tony Varriale wrote:
None of GBIC will do half duplex IIRC. And, they won't do subrate.
The negotiate is there to appease the other end if it tries.
This is painfully common misconception. So some, even serious SPs tend
On (2012-10-24 09:44 +0100), Phil Mayers wrote:
On the plus side, autoneg is mandatory in later versions of the
specs (1000Tx, 10g) IIRC, so maybe this nonsense will finally die?
If I understand 802.3 correctly, you must implement it, but you don't have
to use it, but I might not understand
On 24/10/2012 7:44 PM, Phil Mayers wrote:
The only places we disable autoneg in our network are to connect to same
$FORMER_GOVT_TELCO, which makes me sad :o(
A bit OT, but a similar $FORMER_GOVT_TELCO here in Australia does the
same thing on their business grade ethernet products.
They
On 10/24/2012 1:23 AM, Saku Ytti wrote:
On (2012-10-23 22:06 -0500), Tony Varriale wrote:
None of GBIC will do half duplex IIRC. And, they won't do subrate.
The negotiate is there to appease the other end if it tries.
This is painfully common misconception. So some, even serious SPs tend to
Hi all,
Running up against an odd issue where we have a 3550 with an LX GBIC trying to
talk to a copper port on an ME3600 with a media converter in the middle. The
ME3600 side always shows as up; we disabled fault passthrough on the MC. The
LX GBIC on the 3550 side shows down/down with
If you have an fiber coupler (SC) you can loop TX to RX and verify that
link comes up on the 3550 side on your section of fiber. Also if media
converter has ability to do any internal loop tests (in either direction)
that would be good too.You may be able to plug an ethernet RJ45
loopback
On 10/23/2012 1:40 PM, Jason Lixfeld wrote:
Hi all,
Running up against an odd issue where we have a 3550 with an LX GBIC trying to
talk to a copper port on an ME3600 with a media converter in the middle. The
ME3600 side always shows as up; we disabled fault passthrough on the MC. The
LX