Re: [Elecraft] [KPA500] No power out in OPER mode

2012-04-17 Thread k2zf50
, Apr 16, 2012 10:42 pm Subject: [Elecraft] [KPA500] No power out in OPER mode Today, I was on 15M CW in a pile-up calling, when I looked at the meters I had no output. AMP was in OPER. Put AMP in STBY and I had output, but at the drive level, naturally. I did NOT see any faults or hear a beep. I

Re: [Elecraft] [KPA500] No power out in OPER mode

2012-04-17 Thread KENT TRIMBLE
Guessing is always just guessing. At least one KPA500 has operated flawlessly and nightly since its purchase as a kit more than a year ago. Most recently it performed perfectly for 48 continuous hours at Titanic Special Event Station WØS in Branson, Missouri. On my desk or in the field, it

[Elecraft] [KPA500] No power out in OPER mode

2012-04-17 Thread Dave Johnson
Larry If you use ALC between your KPA500 and your transceiver, check to see if there is a permanent output from the KPA500. U8 on the KPA500 control board is a known issue where the wrong part was specified up to at least serial 573 (mine)... The fix is to obtain the correct part and replace it.

Re: [Elecraft] [KPA500] No power out in OPER mode

2012-04-17 Thread Jack Brindle
Subject: [Elecraft] [KPA500] No power out in OPER mode Today, I was on 15M CW in a pile-up calling, when I looked at the meters I had no output. AMP was in OPER. Put AMP in STBY and I had output, but at the drive level, naturally. I did NOT see any faults or hear a beep. I check all Menu

[Elecraft] [KPA500] No power out in OPER mode

2012-04-16 Thread K2GN
Today, I was on 15M CW in a pile-up calling, when I looked at the meters I had no output. AMP was in OPER. Put AMP in STBY and I had output, but at the drive level, naturally. I did NOT see any faults or hear a beep. I check all Menu items and found them right on the factory settings. I read a