Re: [Elecraft] Broke my K2 :(

2021-07-15 Thread Clay Autery
You can radically mitigate the issue by using a secondary container for that which you'll use in a week or so, and only open the quart/gallon to dispense to working container. I have dry argon in my shack to purge gas space in any container that is hygroscopic or oxidizes in presence

Re: [Elecraft] Broke my K2 :(

2021-07-15 Thread Louandzip via Elecraft
Yep.   I worked at an company where we had some boards with very high impedance circuitry (with the usual guard rings etc.).  We tried many things trying to get wave soldering and aqueous flux to work, but no amount of rinsing washing got the surface conductivity down to where we needed it .

Re: [Elecraft] Broke my K2 :(

2021-07-15 Thread Alan Bloom
Don is exactly right about this.  When I was at HP/Agilent, the company directive was generally not to try to clean the rosin with alcohol.  (Rosin-core solder was used only in rework.)  The rosin contains an acid to help with the soldering, but the acid is locked up inside the rosin where it

Re: [Elecraft] Broke my K2 :(

2021-07-14 Thread Steve Lawrence via Elecraft
99% Isopropyl is available from Uline. Aerospace industry standard is Miller-Stephenson Contact Re-Nu MS-530. Evaporates quickly and leaves no residue. Great stuff but pricey and you'll have to work to find it. GL - Steve WB6RSE > > Yup, it's the 90% stuff. It was impossible to get a year

Re: [Elecraft] Broke my K2 :(

2021-07-14 Thread Don Wilhelm
When I have cleaned boards with IPA or other cleaners, I apply the IPA only in a small spot with a q-tip and then blot it with a paper towel to help dry it - do not flood the board. I generally do not recommend cleaning boards, solder flux is non-conductive and will normally not cause a

Re: [Elecraft] Broke my K2 :(

2021-07-14 Thread jerry
Yup, it's the 90% stuff. It was impossible to get a year ago, but not too bad now. Still, I had to wait a month or so when I ordered it from Amazon. - Jerry KF6VB On 2021-07-14 16:06, John Marvin wrote: Hopefully this is obvious, but make sure you are using the 90-91%

Re: [Elecraft] Broke my K2 :(

2021-07-14 Thread John Marvin
Hopefully this is obvious, but make sure you are using the 90-91% isopropyl alcohol, and not the 70% variety. It can still be hard to get the 90% variety these days. 73, John  - AC0ZG On 7/14/2021 4:41 PM, Peter Eijlander (PA0PJE) wrote: Yes Jerry, isopropyl alcohol does this! I once cleaned

Re: [Elecraft] Broke my K2 :(

2021-07-14 Thread Peter Eijlander (PA0PJE)
Yes Jerry, isopropyl alcohol does this! I once cleaned a working print of a GPS receiver with isopropyl alcohol and it stopped working. Letting it be and trying it again next day turned out it worked perfectly again. From then on I leave a PCB to rest after cleaning to have the IPA dry out

Re: [Elecraft] Broke my K2 :(

2021-07-14 Thread jerry
On 2021-07-07 12:29, Victor Rosenthal 4X6GP wrote: Remember PTTL? Poorly Tinned Toroid Leads. Actually, I suspect that when I scrubbed it with isopropyl alcohol, it shorted out one or more high-impedance crystals; because at one point, it was tuning WWV with no heterodynes - just like an AM

Re: [Elecraft] Broke my K2 :(

2021-07-07 Thread Victor Rosenthal 4X6GP
Remember PTTL? Poorly Tinned Toroid Leads. Look for them. 73, Victor, 4X6GP Rehovot, Israel CWops #5 Formerly K2VCO https://www.qsl.net/k2vco/ On 07/07/2021 22:19, jerry wrote: So I went out this morning to replace the CW filters with the upgrade kit. Unsoldered the 5 crystals. Removed one of

[Elecraft] Broke my K2 :(

2021-07-07 Thread jerry
So I went out this morning to replace the CW filters with the upgrade kit. Unsoldered the 5 crystals. Removed one of them - whups, it's got the "S"! That means that the upgraded crystals are already installed. I thought there was no "S" - it was hard to read with them installed. So I