Re: [Emc-developers] automatic

2014-09-25 Thread Gene Heskett
On Thursday 25 September 2014 06:12:34 David Armstrong did opine And Gene did reply: > i'm working on a automatic gearchanger comp , switching between auto , > low or high > this works fine , excepting being able to select between 2 encoder > parameter scales depending on gear chosen . > > the er

Re: [Emc-developers] automatic

2014-09-25 Thread sam sokolik
for even more ideas. (this is pretty specific to the K&T gearbox...) but might give ideas.. (maybe on what not to do.. ;) ) http://electronicsam.com/images/KandT/conversion/testing/config/gearshift16.comp I obviously am not the greatest programmer but the comp has never given us problems. ht

Re: [Emc-developers] automatic

2014-09-25 Thread andy pugh
On 25 September 2014 11:12, David Armstrong wrote: > the error i have is that the the 5i20.scale does not exist The encoder scale is listed as an r/w pin, rather than a parameter. (assuming you mean 5i20.0.enoder.00.scale? ) I am not sure if you would really want to change the encoder scale in m

[Emc-developers] automatic

2014-09-25 Thread David Armstrong
i'm working on a automatic gearchanger comp , switching between auto , low or high this works fine , excepting being able to select between 2 encoder parameter scales depending on gear chosen . the error i have is that the the 5i20.scale does not exist i have the 2 values just fine , it's placing