UKAS/NAMAS

1998-06-02 Thread Pryor McGinnis
I have a client with electronic controlled flow meters who is in need of testing/certification by a UKAS/NAMAS Accredited laboratory. Because of the flow meter, I believe Weights Measures plus EMC will be required. Does anyone know of an efficient path for this certification? Pryor

Re: interceptor voltage stabilizer

1998-06-02 Thread Chris Dupres
Peter, David, Brian et al, et al. Peter, you wrote: Could anyone provide a description to the list of what the voltage stabilizer is supposed to do and how it is accomplished? Possibly a contraption can be made from electronic components. The 'Voltage stabiliser', as it is known , is a very

The Santa Clara EMC Colloquim

1998-06-02 Thread Douglas Mckean
I'd just like to say that it was nice to finally put some faces to the names. Thought it went very well.

Re: Radio Approvals

1998-06-02 Thread Doug . Kealey
Sam, For starters, have you tried these web sites? http://www.etsi.fr (ETSI) http://global.ihs.com (Global Engineering Documents) Or call the UK Dept of Trade and Industry in London. Ask for the Radio Regulatory Division. I can get a

Re: PCI edgecard vs. compact

1998-06-02 Thread HMellberg
In general reliability terms, one connector is better than two. But, if the lack of connector allows for warpage and hence, reduced contact pressure at certain locations, then it is a toss-up. Secondly, without the use of the second connector, the pad contact material becomes significantly

Re: where are X and Y caps required?

1998-06-02 Thread jwonyoo
Dear Eszlari; In the CSA standard are obviously described that Varistor can be used after fuse if comply with flammable test (If use enclosure of Varistor as UL 94-5V) The detail description is below; In the CSA 22.2 No.1 If Varistor use for across-the-line use, the Varistor shall be

RE: Radio Approvals

1998-06-02 Thread EMC PSTC
Sam, There is no dedicated forum that I am aware of. As for ETS 300 113, Issue 1 was published in January 1992 with Issue 2 following in June 1996. The second edition has been amended once in March 1997. There are no further published amendments. Regards, James

Glow-wire Test

1998-06-02 Thread jwa-won Yoo
Hi everyone ! I have some question about Glow-wire test (IEC 695-2-1) There are written by some kinds of glow wire temperature degree 550 to 960. In the standard, IEC 335-1, separated degree of glow-wire test based on attended appliance , current carrying part ( over 0,5mA) and insulation

Position Available - Tech. Support Engineer

1998-06-02 Thread Todd Robinson
Technical Support Engineer Position Overview CKC Laboratories, Inc. is a growing EMC engineering and testing services business, head-quartered in beautiful Mariposa, California. We are currently seeking a career minded individual who enjoys employment in a fast paced, high-technology, team

FW: Position Available - CSR

1998-06-02 Thread Todd Robinson
Customer Service Representative Position Overview CKC Laboratories, Inc. is a growing EMC engineering and testing services business, head-quartered in beautiful Mariposa, California. We are currently seeking a career minded individual who enjoys employment in a fast paced, high-technology,

FW: Position Available - TSR

1998-06-02 Thread Todd Robinson
Technical Sales Representative Position Overview CKC Laboratories, Inc. is a growing EMC engineering and testing services business, head-quartered in beautiful Mariposa, California. We are currently seeking a career minded individual who enjoys employment in a fast paced, high-technology, team