RE: Australian RF lab

2001-12-11 Thread Cameron O'phee
Try EMC Technologies at http://www.emctech.com.au/ Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile : +61 2 9663 1412 Mobile : 0418 464 016 -Original Message- From: richwo...@tycoint.com

RE: Importing to Australia with a twist

2001-09-20 Thread Cameron O'phee
to state but is regulated by the Dept of Fair Trading in New South Wales. Compliance in one state assures compliance Australia wide. As others have said, good luck. Regards, Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile

RE: ESD Testing

2001-08-15 Thread Cameron O'phee
for the best!! Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile : +61 2 9663 1412 Mobile : 0418 464 016 -Original Message- From: wo...@sensormatic.com [mailto:wo...@sensormatic.com] Sent: 14 August, 2001 23

RE: Australia Standards

2001-07-25 Thread Cameron O'phee
Hi George, You could also try Testing and Certification Australia at http://www.tcaust.com/elecsafe.htm for some advise. As the name implies, they are a test house. Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile

Australian power cable requirements.

2001-05-02 Thread Cameron O'phee
insists that the cordage must be H05VVF. Consequentely, I would like to know the difference in requirements between the US SJT cordage and European H05VVF. Regards, Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile

RE: Risk assessment

2000-12-07 Thread Cameron O'phee
to link up your input assessments, the last line will point to the associated risk level. It's a bit difficult to describe verbally. Let me know if you would like more details. Regards, Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420

Ground potentials and communications.

2000-12-07 Thread Cameron O'phee
to the chassis ground of the machine. I am concerned that ground potentials between machines on different circuits could be enough to be a safety concern however the safety standard (AS3260) our equipment is tested to does not seem to cover this scenario. Any thoughts or information? Regards, Cameron

Surge testing.

2000-10-20 Thread Cameron O'phee
to adopt are not excessive. Regards, Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile : +61 2 9663 1412 Mobile : 0418 464 016 --- This message is from the IEEE EMC Society Product

RE: Power Line Voltages

2000-10-05 Thread Cameron O'phee
Hi Randy, Try this link. http://www.ets-tele.com/tics/global/volt_freq.htm http://www.ets-tele.com/tics/global/volt_freq.htm Regards, Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile : +61 2 9663 1412 Mobile

RE: Probing power plane with analyser

2000-10-03 Thread Cameron O'phee
frequencies of interest extend to 300MHz, the LISN is not much of an option. The testing will initially only involve A:B comparisons so I feel satisfied that it should be safe enough to proceed with the DC blocking capacitor method. Regards, Cameron O'Phee. EMC Safety Precompliance. Aristocrat

Probing power plane with analyser.

2000-09-28 Thread Cameron O'phee
no designs for this application. Does anyone have any ideas on how I can safely probe a 3v DC power rail with an EMC analyser (HP8591E)? Regards, Cameron O'Phee. EMC Safety Precompliance. Aristocrat Technologies Australia. Telephone : +61 2 9697 4420 Facsimile : +61 2 9663 1412 Mobile