Re: CE test suite for computers

2001-08-28 Thread John Woodgate
I read in !emc-pstc that George, David L george.da...@unisys.com wrote (in 3B10FF0A008FF6458711E6E375E830412C16A6@USTR- EXCH2.na.uis.unisys.com) about 'CE test suite for computers', on Mon, 27 Aug 2001: John: After all your years on the committee and having heard all the technical arguments, I am

RE: CE test suite for computers

2001-08-27 Thread George, David L
[mailto:j...@jmwa.demon.co.uk] Sent: Saturday, August 18, 2001 1:55 PM To: emc-p...@majordomo.ieee.org Subject: Re: CE test suite for computers I read in !emc-pstc that Tania Grant taniagr...@msn.com wrote (in oe127msph2q6dqajy4k4...@hotmail.com) about 'CE test suite for computers', on Sat, 18 Aug

RE: CE test suite for computers

2001-08-20 Thread Stone, Richard A (Richard)
Don't forget Telco Conducted Emissions is NOT required until at least 2003' Richard, -Original Message- From: Frazee, Douglas (Douglas) [mailto:dfra...@lucent.com] Sent: Friday, August 17, 2001 12:19 PM To: 'Pettit, Ghery'; 'Stuart Lopata'; emc Subject: RE: CE test suite for computers

Re: CE test suite for computers

2001-08-19 Thread John Woodgate
I read in !emc-pstc that Tania Grant taniagr...@msn.com wrote (in oe67wwnyumtlor31l1g0002c...@hotmail.com) about 'CE test suite for computers', on Sat, 18 Aug 2001: Thank you, Mr. Woodgate,   I am sure many of the American contingent are grateful for your explanation. I note the

Re: CE test suite for computers

2001-08-19 Thread Tania Grant
Thank you, Mr. Woodgate, I am sure many of the American contingent are grateful for your explanation. taniagr...@msn.com - Original Message - From: John Woodgate Sent: Saturday, August 18, 2001 3:25 PM To: emc-p...@majordomo.ieee.org Subject: Re: CE test suite for computers I

Re: CE test suite for computers

2001-08-19 Thread Tania Grant
Rich, Thank you very very much. taniagr...@msn.com - Original Message - From: Rich Nute Sent: Saturday, August 18, 2001 3:02 PM To: taniagr...@msn.com Cc: j...@jmwa.demon.co.uk; emc-p...@majordomo.ieee.org Subject: Re: CE test suite for computers Hi John and Tania: Actually

Re: CE test suite for computers

2001-08-19 Thread Ken Javor
observation and not a proven cause and effect. -- From: Rich Nute ri...@sdd.hp.com To: taniagr...@msn.com Cc: j...@jmwa.demon.co.uk, emc-p...@majordomo.ieee.org Subject: Re: CE test suite for computers Date: Sat, Aug 18, 2001, 4:10 PM Hi John and Tania: Actually, the harmonic current

Re: CE test suite for computers

2001-08-19 Thread John Woodgate
I read in !emc-pstc that Rich Nute ri...@sdd.hp.com wrote (in 200108182110.oaa02...@epgc196.sdd.hp.com) about 'CE test suite for computers', on Sat, 18 Aug 2001: The basic problem is that the harmonic currents generated in the load equipment are dissipated in the delta primary of a delta-wye

Re: CE test suite for computers

2001-08-18 Thread John Woodgate
I read in !emc-pstc that Tania Grant taniagr...@msn.com wrote (in oe127msph2q6dqajy4k4...@hotmail.com) about 'CE test suite for computers', on Sat, 18 Aug 2001: Most people will never understand anything unless it is explained to them.  Merely stating that the power distribution

Re: CE test suite for computers

2001-08-17 Thread John Woodgate
I read in !emc-pstc that Rich Nute ri...@sdd.hp.com wrote (in 200108171905.maa00...@epgc196.sdd.hp.com) about 'CE test suite for computers', on Fri, 17 Aug 2001: Agreed! Well, see my direct response to G. P. EN 61000-3-2 is driven by Euro power distributors who don't want to correct for

Re: CE test suite for computers

2001-08-17 Thread John Woodgate
I read in !emc-pstc that Pettit, Ghery ghery.pet...@intel.com wrote (in d5e932f578ebd111ac3f00a0c96b1e6f09506...@orsmsx31.jf.intel.com) about 'CE test suite for computers', on Fri, 17 Aug 2001: Also EN 61000-3-3 needs to be considered.  Useless standards, if you ask me.   That's

Re: CE test suite for computers

2001-08-17 Thread Rich Nute
Hi Ghery: Also EN 61000-3-3 needs to be considered. Useless standards, if you ask me. Agreed! EN 61000-3-2 is driven by Euro power distributors who don't want to correct for non-linear loads. (But who have no quarrel with correcting for phase angle.) I don't understand the drive for

RE: CE test suite for computers

2001-08-17 Thread Pettit, Ghery
Also EN 61000-3-3 needs to be considered. Useless standards, if you ask me. Ghery -Original Message- From: Frazee, Douglas (Douglas) [mailto:dfra...@lucent.com] Sent: Friday, August 17, 2001 9:19 AM To: 'Pettit, Ghery'; 'Stuart Lopata'; emc Subject: RE: CE test suite for computers

RE: CE test suite for computers

2001-08-17 Thread Frazee, Douglas (Douglas)
, Ghery [mailto:ghery.pet...@intel.com] Sent: Thursday, August 16, 2001 4:39 PM To: 'Stuart Lopata'; emc Subject: RE: CE test suite for computers Stuart, For ITE the requirements are EN 55022:1994 (through 1 August 2003) and EN 55024:1998. If you wish to test to anything else, you need to go

Re: CE test suite for computers

2001-08-16 Thread John Woodgate
I read in !emc-pstc that Stuart Lopata stu...@timcoengr.com wrote (in 00d301c12687$8b6e8100$1301a8c0@newberry) about 'CE test suite for computers', on Thu, 16 Aug 2001: Any info about the test suite for computers (for commercial professional markets in EU) to meet the EMC directive for the CE

RE: CE test suite for computers

2001-08-16 Thread Pettit, Ghery
Stuart, For ITE the requirements are EN 55022:1994 (through 1 August 2003) and EN 55024:1998. If you wish to test to anything else, you need to go through a Competent Body and convince them that the alternate standards are adequate. Ghery Pettit Intel -Original Message- From: Stuart