gt;, Antonin Skoch
mailto:a...@ikem.cz>>
Cc: HCP Users
mailto:hcp-users@humanconnectome.org>>
Subject: Re: [HCP-Users] gradunwarp - "array index out of bounds" error in
coef_file_parse routine
I have made this change and released version v1.0.3 of gradunwarp with this
I have made this change and released version v1.0.3 of gradunwarp with
this fix.
Thanks,
Tim
On 10/17/2016 11:21 AM, Keith Jamison wrote:
That is the correct fix for this problem. It has no side-effects.
Some scanners (eg: Siemens 7T) have coefficients of even higher
orders, so you can act
That is the correct fix for this problem. It has no side-effects. Some
scanners (eg: Siemens 7T) have coefficients of even higher orders, so you
can actually increase the siemens_cas to 100 or so to accommodate the full
range. That value just determines the preallocation, and the matrix is
trimm
Dear experts,
I have an issue with processing my data (acquired at Siemens Prisma 3T) by
gradunwarp v1.0.2, downloaded from
https://github.com/Washington-University/gradunwarp/releases
It crashed with my coef.grad file by producing "array index out of bounds"
error in coef_file_parse routine.