Hello,
I am running z/OS 1.12. and I use "SYS1.MODGEN(IEZVX100)" when I write
programs to go against the SYSLOG.
*/* DESCRIPTIVE NAME: COMMUNICATIONS TASK INSTALLATION EXIT @P6C*/
*/*ROUTINE PARAMETER LIST@P6A*/
Thanks...Guy M. Gates Jr.
TTI Z/OS
Hello,
Has anyone mentioned that you need to turn on the environment before you
address SDSF and turn it back off when you are done?
i.e.
RC=ISFCALLS('ON')
ADDRESS SDSF "ISFEXEC SR"
...More Processing here...
RC=ISFCALLS('OFF')
EXIT
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Program
John,
You are in my prayers for Gods healing and comfort. May God guide the doctors
so that you may be back on your feet soon.
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer II
Email: guy.ga...@ttiinc.com
"Mainframe-inspired reliability for optimal system uptime.
You are in my prayers, May your recovery be swift.
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer II
Email: guy.ga...@ttiinc.com
"Mainframe-inspired reliability for optimal system uptime."
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-
Hi Everyone,
Currently we run with our Mainframes in a separate VLAN from other
environments, such as Intel and Unix. We have been asked to research
putting all of the environments on the same VLAN. My question is, What
are other shops doing? DO you run with your Mainframes in a separate
VLAN,
NPRO=5 means that 5 seconds after the last print job the printer will
'run out' the report to the output stacker. What you have to watch out
for is that a print comes out 5 seconds later the printer runs it to
the output stacker... then 10 seconds later another job prints then
5 seconds lat
Hi All,
She is asking about her SYSRES volume. Is anyone running with their SYSRES in
an SMS Pool or Storage Group?
Does IBM even support a SYSRES being in a SMS POOL? I was under the impression
that it is not supported, but I could be wrong.
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Pro
I found this by hitting PF1 on the Status Screen. I am running z/OS
1.10.
PhaseName Name of the job phase. Tab to Phase and
press F1 for details.
Phase Number of the job phase
I do not know what AWAIT MAIN SELECTION means. Are you in
Hi,
I sent them an Email and got this reply...
Hello Guy Gates:
We are experiencing technical difficulties. Work is underway to resolve
the problem as soon as possible. We apologize for the inconvenience
this
has caused you.
Thank you for your interest in Announcement Letters.
The Global A
Hi,
We use NEXUS currently, and used Reflections in the past.
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer II
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with
Hello,
My programming staff wants to investigate installing TableBase on our
systems to help speed up the nightly batch jobs. I have heard the sales
pitch,
but would be interested in hearing from those on this list whom have had
experience with TableBase.
You can contact me Off-List with y
Hi,
Just a thought. I had a user with a similar problem as he wanted to set
his screen size to 35x155 and started to fail when I installed z/OS
1.10. What we found out was that in TSOKEY00 the buffersizes were too
small to support it and when we increased them he was able to use the
larger screen
Hello,
Thanks to all who responded.
I understand about the DEVSUPxx stuff. Setting categories for each
LPAR. (i.e. LPAR1 = 0010, LPAR2 = 0020) This I can do.
Each LPAR uses separate VOLSER ranges so it shouldn't be too difficult
to isolate them using OPENRULE and PRTITION. Although I need to
The z/OS V1R8.0 DFSMS Storage Administration Reference has this for the
Write Statement
At execution and allocation time, an end user can receive a maximum of
five messages. If any more messages are generated, a sixth and final
message indicates that additional messages have been generated,
Hi,
What is the activity on other paths between these two systems?
How many paths do you have defined?
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer II
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Steve Grimes
Sent: Friday, Fe
We use MacKinney Systems JQP. Works Great, Reasonably Priced.
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer II
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Paul Schuster
Sent: Tuesday, February 19, 2008 11:56 AM
To: IBM-MAIN@BAMA
Does this Dataset have an Alias assigned to it? I used to work at a
shop that used a lot of Dataset Aliases and when we did a 3.4 List we
got two entries, One for the Alias and One for the Real Dataset. I don't
remember if there was an option to suppress listing two entries, but I
think there was.
Hello,
I found RTA000189025 while searching SIS on SERVICELINK.
Parallel sysplex with LPARs PC90 z/OS 1.4 and PC9A test system on z/OS
1.7. No MAS.
MASDEF has share=nocheck
Installation is pondering over RNL specification for JES2 after
experiencing $HASP9201 JES2 MAIN TASK WAIT DETECTED AT IS
Check this link out, I think it has what you are looking for. Both the
703 and 506 are shown.
http://www.tech-news.com/publib/pl2094.html
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer II
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf
Greetings,
I am working on sizing a new processor to carry us through the next few
years. During the discussions, It was asked if the additional capacity
that we are adding, If there is available Capacity to handle a
Relational Database. We are not using a Relational Database today.
My question
>2: the 144GB disk rotate at the same speed as the 72GB, so
>basically they can deliver the same amount of MB/sec.
My DS8100 has 146GB Drives at 10k RPM and 73GB Drives at 15k RPM.
Doesn't this indicate that my 73GB Drives are Faster and can deliver
more MB/Sec? Or is there something in the DS81
Hello,
We had the same problem when we went to Z/OS 1.6. I found that the
Command Program was clearing MCSOPPRM which includes the MCS Authority.
I turned it back on with the intruction 'OIMCSOATH1,MCSOMSTR' in the
Assembler Program. Might be a place to look at.
Thanks...Guy M. Gates Jr.
TT
Robert,
Why 4300 Cylinders for &&WORK01 and only 5 Cylinders for TRAM1.WORK1??
Stupid Question: Can a &&TEMP Dataset span a volume? Or is this a Mod-9 or
Mod-23??
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer
Phone: (817) 740-9000 x-4627
Email: [EMAIL PROTECTED]
Greetings,
Is there an way to print all the VRS records from RMM? I tried to
create a User Report to list them, but I don't know enough about RMM to
get it to run. Any assistance would be greatly appreciated.
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer
Phone: (817) 740-9000 x-4627
Em
Hi Dennis,
It is in the RMF User's Guide.
I'm running Z/OS 1.6 and found it here:
Title: z/OS V1R6.0 RMF User's Guide
Document Number: SC33-7990-09
In this Directory:
http://publibz.boulder.ibm.com/bookmgr_OS390/libraryserver/zosv1r6/
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer
Greetings,
Take a look at II14008 as it describes this situation.
Thanks...Guy M. Gates Jr.
TTI Z/OS Systems Programmer
Phone: (817) 740-9000 x-4627
Email: [EMAIL PROTECTED]
-Original Message-
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Imbriale, Donal
Hello Rob,
The Prefix information for a User is stored in the ISPF Profile
Dataset in Member ISPPROF. If you have the RACF Authority, You can view
the users Profile Dataset (Usually something like &Userid.ISPF.PROFILE).
Or the user can display it by issuing the 'TSO PROFILE' Command on the
ISPF
At a previous employer, We had just completed building a new Computer
Center. This building was in the same area as others that this company
owned, So they were going to use the same cleaning company that the
other buildings used. Our building had sensors that unlocked the door as
you approached,
Hi Peter,
We are converting from VSE to Z/OS and my management was asking the
same question. Did you keep track of the numbers that you can share back
to the list? It looked like a lot were IPL'ing Weekly, with a trend to
move to fewer IPL's as Business Criticality Increased. Was that what you
sa
29 matches