Re: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

2006-11-27 Thread François Paré
ND IN SYS1.PARMLIB On Mon, 27 Nov 2006 14:42:54 -0500, François Paré <[EMAIL PROTECTED]> wrote: >I'm not able to do a complete first IPL of a new cloned system. It stopped with the following messages: > >IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB > >IEA510A LNKLST PROCESSING

Re: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

2006-11-27 Thread Randy Gross
look for a missing comma in ieasysxx -Original Message- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] Behalf Of François Paré Sent: Monday, November 27, 2006 2:43 PM To: IBM-MAIN@BAMA.UA.EDU Subject: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB Hello, I'm not ab

Re: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

2006-11-27 Thread McKown, John
> -Original Message- > From: IBM Mainframe Discussion List > [mailto:[EMAIL PROTECTED] On Behalf Of François Paré > Sent: Monday, November 27, 2006 1:43 PM > To: IBM-MAIN@BAMA.UA.EDU > Subject: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB > Hello, > > I'm

Re: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

2006-11-27 Thread Mark Zelden
On Mon, 27 Nov 2006 14:42:54 -0500, François Paré <[EMAIL PROTECTED]> wrote: >I'm not able to do a complete first IPL of a new cloned system. It stopped with the following messages: > >IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB > >IEA510A LNKLST PROCESSING IS INOPERATIV

Re: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

2006-11-27 Thread Alan C. Field
Ah - but do you have a member in PARMLIB named LNKLST00? Even if it is a null member. I think that is what the message is telling you. You might have a list of datasets that will become your linklisted datasets in PROG00 Alan -

Re: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

2006-11-27 Thread Schwarz, Barry A
06 11:43 AM To: IBM-MAIN@BAMA.UA.EDU Subject: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB Hello, I'm not able to do a complete first IPL of a new cloned system. It stopped with the following messages: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB IEA510A LNKLST PROCESSING IS INOPERAT

IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB

2006-11-27 Thread François Paré
Hello, I'm not able to do a complete first IPL of a new cloned system. It stopped with the following messages: IEA301I LNKLST00 NOT FOUND IN SYS1.PARMLIB IEA510A LNKLST PROCESSING IS INOPERATIVE, PRESS ENTER TO CONTINUE WITH THE DEFAULT LNKLST, OR RE-IPL THE SYSTEM The message