Hi,
currently we have a TR link going into a FEP which connects via bus and tag to
a 9034 which then connects via ESCON to a z196, but we're going z13 and so need
FICON link. The CNA8000 would appear to be able to replace both the FEP and
the 9034 if we configure it right as it has TR and FICO
On 2017-07-21, at 18:38, Jesse 1 Robinson wrote:
> Another mystery. The full.txt HOLDDATA file contains no ++ASSIGN entries at
> all.
>
Don't those have to appear in SMPPTFIN, whereas ++HOLD appears in SMPHOLD
(except for SYSTEM, which may appear in either.)
(Well, I've put ++ASSIGN only in S
Another mystery. The full.txt HOLDDATA file contains no ++ASSIGN entries at
all.
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
robin...@sce.com
-Original Message-
From
We may have the answer for this PTF and probably others in a similar state.
FMID HNVL11B is SUPBY HNVL12B in the target, but there are remnants of it in
the GLOBAL *not* including the FMID entry itself.
OTOH the full.txt file I just pulled does not mention UA74273 at all.
.
.
J.O.Skip Robinso
Maybe try a REPORT SOURCEID and see if any RSU show up.
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Jesse 1 Robinson
Sent: Friday, July 21, 2017 6:27 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: What to do with PTF dogies?
CAU
This may be at least in part a mechanical problem. Before I open an SR, I'd
like to show one example. In our GLOBAL, UA74273 looks like this:
SOURCEID ALLAVAIL
ORD00020
PUT1410
SMCCOR
No RSU assigned. However, SIS shows this:
RSU ... 1503
We rout
That's sorta what we ended up doing. Only used the DCF to create a Post
Script file as input to AUTOCAD.
In a message dated 7/21/2017 7:31:30 A.M. Central Daylight Time,
randy.hoeks...@haworth.com writes:
HCD option 4 Create or view graphical configuration report will create a
DCF outpu
For what it's worth, here is the parts of my I/O configuration which deals with
the CTC. Sorry for the long post, but we do have cross CSS definitions which
are active. Please note the CUADD is the DESTINATION LPAR. The first digit of
the CUADD is the CSS, the second digit is the LPAR.
CHPID
Thanks Jerry, that helps.
Jerry Whitteridge wrote:
Tom - Think of the DLM as the head of string Tape controller (from the old
days) that provides the UCB's. Then there is some form of Storage attached
(think the physical tape that got mounted) - in our case this is a DD4500 as
an example. EM
Don't believe multiple channel subsystems should be an issue if the CPC
supports it. CUADD=03 represents a combination of CSS 0 and MIF image ID 3.
What does your CHPID PATH=(CSS(0),08) look like? L05 and L06 are in the access
list?
Regards,
Kevin
-Original Message-
From: IBM Mainfr
Had a similar problem once with an MVS upgrade. A (very savvy) user called up
and reported getting a JCL with a very old job. On closer inspection he
discovered some error with a comma. Job had run for years with no problem.
Suddenly boom. Grin and move on.
I could see a larger issue with lots
Tom - Think of the DLM as the head of string Tape controller (from the old
days) that provides the UCB's. Then there is some form of Storage attached
(think the physical tape that got mounted) - in our case this is a DD4500 as
an example. EMC allows only certain Storage to attach to the DLM.
J
In my limited experience with DD (Data Domain) and DLM (emulated virtual tape)
the issues we had was time to replicate and since we wanted the less-expensive
solution we shared our DD with the distributed systems.
We replicated to a local DR site, over black fiber and to a DR site almost 800
mi
I don't have the answer to that one. I imagine it's possible! But I don't
believe there was any specific intent for this to "uncover bad code" in 6.1, so
you'll probably just have to see what you run in to with 6.2.
Frank
From: IBM Mainframe Discussion List o
I did some tests with another Vendor similar to DellEMC solution moving data
from virtual tape to cloud and results was not good. A bigger bigger reclaim
time to get dataset available to mainframe, and very expensive.
I need to store about 240TB in cloud and cost quiet project. We buy more
midra
Thanks Frank.
I agree this is bad code.
I was curious if the new COBOL 6.2 compiler would uncover any other bad code.
I like that it is identified at compile time.
Sent from my iPhone
> On Jul 21, 2017, at 11:55 AM, Frank Swarbrick
> wrote:
>
> The error is not that there is a VALUE clause
I completely agree this was at best a hidden error previously
My question was not so much how to work around it but whether there were other
similar nuggets with COBOL 6.2
Sent from my iPhone
> On Jul 21, 2017, at 11:48 AM, Bernd Oppolzer
> wrote:
>
> This has already been brilliantly explai
I'm new to this so I can't answer your question yet, but thanks for
responding and for the web reference. And by coincidence I also see
your DLM post about cloud too!
Lizette Koehler wrote:
Tom
I may be wrong, but the DLm is more like a database for the tapes. There is no
storage on it. Th
Thanks Radoslaw, I appreciate it.
R.S. wrote:
W dniu 2017-07-21 o 04:27, Tom Brennan pisze:
Is anyone using a Quantum (quantum.com) device to back up data from an
EMC DLM? (Disk Library for Mainframe - looks like tape to the mainframe)
AFAIK it is not possible since EMC limited DLM to conn
The error is not that there is a VALUE clause in the linkage section, but
rather the value clause now being allowed and respected, in conjunction with
the fact that the particular value clause is invalid. It should be VALUE
'1234', not VALUE 1234. You would get the same error in COBOL V4 and V
This has already been brilliantly explained by Frank Swarbrick;
the new COBOL compiler version has a new INITIALIZE statement
which is able to INITIALIZE variables of the LINKAGE SECTION,
so that the VALUEs coded there are not comments any more,
but instead the have a meaning !!
In the past, whe
Here is a snippet from someone else's observations:
Hi
Just wondering has anyone confronted this compile issue stated for COBOL 6.1?
Version 6.1
COBOL source code differences in Enterprise COBOL Version 6
In Enterprise COBOL V5 and earlier versions, a non-88 level VALUE clause in the
LINKAG
I would, if there's no need to cross CSS's I would
Carmen
- Original Message -
From: "Dave Jones"
To: IBM-MAIN@LISTSERV.UA.EDU
Sent: Friday, July 21, 2017 9:57:33 AM
Subject: Re: IOCDF issue
All of the CTC devices at 73xx are offline and not available. so it's not just
7302 and
All of the CTC devices at 73xx are offline and not available. so it's not just
7302 and 7303, either.
Maybe I should delete all CTCs out of the IOCDS and recreate them all in the
same CSS...?
--
For IBM-MAIN subscribe / signof
W dniu 2017-07-21 o 16:32, Lizette Koehler pisze:
http://www.storagereview.com/dell_emc_announce_dlm_45_to_eliminate_physical_tape
Today at SHARE 2017, Dell EMC announced the latest version of its Disk Library
for mainframe (DLm) virtual tape, version 4.5. The latest version of Dell EMC's
cloud
It would have to be a big improvement over the last iteration. we had many
issues with a DR DD and DLM from Arkansas to Boulder.
- Original Message -
From: "Lizette Koehler"
To: IBM-MAIN@LISTSERV.UA.EDU
Sent: Friday, July 21, 2017 9:32:28 AM
Subject: EMC DLm to the Cloud
http://w
Since it seems its only one or two devices I have to assume the Chanel path is
online? to all LPARS
since FCTC are all LPARS on the same physical box?
maybe plugged into the wrong PCHID?
- Original Message -
From: "Dave Jones"
To: IBM-MAIN@LISTSERV.UA.EDU
Sent: Friday, July 21,
Hello, Lizette.
Sorry no MVS here, this is a pure z/VM complex running on a z12.
The system is about 1200 miles away from where I am, so I can't tell if any
lights on the cables are on or notI do have access to the HMC, thou.
I'm asking here on IBM-MAIN because I suspect there is a lot mor
Agree, I've never had the need to cross channel subsystem or CSS's either
- Original Message -
From: "Doug"
To: IBM-MAIN@LISTSERV.UA.EDU
Sent: Friday, July 21, 2017 9:32:31 AM
Subject: Re: IOCDF issue
Never tried crossing CSS for FCTC.
Spanned channels perhaps?
Regards, Doug
.
Never tried crossing CSS for FCTC.
Spanned channels perhaps?
Regards, Doug
.
On Jul 21, 2017, at 10:24, Lizette Koehler wrote:
Can you issue the
D M commands
DEV Serve commands - DS Q for example
And see what MVS and IOS thinks?
I do not have the syntax in front of me.
Are any of the dev
http://www.storagereview.com/dell_emc_announce_dlm_45_to_eliminate_physical_tape
Today at SHARE 2017, Dell EMC announced the latest version of its Disk Library
for mainframe (DLm) virtual tape, version 4.5. The latest version of Dell EMCs
cloud-based virtual tape is aiming to replace physical ta
Hi, Carmen.
The actual message is this:
"Device 7302 cannot be varied online because no channel path is available."
I don't know if that means the fiber is plugged in or not.
Thanks.
DJ
--
For IBM-MAIN subscribe / signoff / arc
Can you issue the
D M commands
DEV Serve commands - DS Q for example
And see what MVS and IOS thinks?
I do not have the syntax in front of me.
Are any of the devices on 7300 available and it is just 7302 and 7303 that are
not available?
Do the connections have light end to end
Lizette
>
looking again, I wonder about
IODEVICE ADDRESS=(7000,032),CUNUMBR=(7000),STADET=Y, *
> PARTITION=((CSS(2),L24)),UNIT=FCTC
last time I did a gen was back y2k, :(
- Original Message -
From: "Dave Jones"
To: IBM-MAIN@LISTSERV.UA.EDU
Sent: Friday, July 21, 2017 8:44:37 AM
Subject:
Is there a physical connection between these LPARS , fiber in/out ?
is the message no physical paths available ?
just eyeballing the gen looks correct
Carmen
- Original Message -
From: "Dave Jones"
To: IBM-MAIN@LISTSERV.UA.EDU
Sent: Friday, July 21, 2017 8:44:37 AM
Subject: IOCDF
Hello, guys.
I'm stuck here with an IOCDS problem that I can't figure out and need the help
of some experts.
Here's the problem...I have an IOCDS that looks like this:
> *ICP ICP152I SYSTEM=(2827,1) USED BY ICP IOCP
> RESOURCE PARTITION=((CSS(0),(L01,1),(L02,2),(L03,3),(L04,4), *
>
HCD option 4 Create or view graphical configuration report will create a DCF
output file when you choose Output = 2. I found a DCF to HTML REXX that will
convert the downloaded file to HTML, the output is not perfect but very
useable. I ran it on my Windows machine using the Regina REXX Interpre
I would ask the same question - what's the end-goal? If you're just trying to
test something or revive some old gear for a while, an IBM 8229 LAN Bridge can
be had for bugger all off eBay. It just bridges traffic between an Ethernet
LAN and a token ring LAN. If this is a more permanent thing,
Tom
I may be wrong, but the DLm is more like a database for the tapes. There is no
storage on it. The needs to be another piece of equipment to provide the
storage for the actual tape usage.
I think you are asking can you use a storage device other than EMC equipment to
hold the actual tape dat
W dniu 2017-07-21 o 07:49, Peter Bishop pisze:
Hi,
we have a possible need to connect a token-ring link to a z13 (don't ask) and
were considering one option, but now another has appeared.
We're wondering if anyone else is using a Visara CNA8000 for this? It seems a
simpler option than the ot
W dniu 2017-07-21 o 04:27, Tom Brennan pisze:
Is anyone using a Quantum (quantum.com) device to back up data from an
EMC DLM? (Disk Library for Mainframe - looks like tape to the mainframe)
AFAIK it is not possible since EMC limited DLM to connect only to EMC
storage.
Before that DLM was name
41 matches