There are many of them. Some of my clients use products from mackinney.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Wed, Jun 9, 2021 at 9:35 PM Pommier, Rex wrote:
> $AVRS by
k you for your kind thoughts!
>
> Billy
>
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
--
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Conti
I am able to access task hmc-service-representative-tasks, but this a
deadend. it does not have URIs to the required data.
Itschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/
---
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
> --
reputation merely what others think you are." - - - John Wooden
>
>
>
>
> --
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
--
*| **Itschak Mugzach | Director | SecuriTeam Software **|**
I am looking for an api to collect TWS configuration (anything that reads
from parmlib parmlib). The APIs I reviewed are for management. Tx for your
ideas.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM co
If not already mentioned, see redbooks series ABCs of IBM z/OS System
Programming (13 volumes). Link to vol-1:
https://www.redbooks.ibm.com/abstracts/sg246981.html?Open
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **|
If you have the same message id and ame answer, consider use of z/os auto
replay (see parmib).
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Thu, Apr 29, 2021 at 5:05 PM John Mc
Tried that with non auth user and it work
בתאריך יום ד׳, 28 באפר׳ 2021 ב-16:40 מאת David Crayford :
> getpwent requires SAF access or super user.
>
> > On 28 Apr 2021, at 9:24 pm, Itschak Mugzach <
> 0305158ad67d-dmarc-requ...@listserv.ua.edu> wrote:
> >
&
getpwent But what about ?
בתאריך יום ד׳, 28 באפר׳ 2021 ב-16:22 מאת Paul Gilmartin <
000433f07816-dmarc-requ...@listserv.ua.edu>:
> On Tue, 27 Apr 2021 15:32:12 +0300, Itschak Mugzach wrote:
>
> >Have a look at getpwent. If I am not allowing a user to list RACF users,
>
is retrieved.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
--
For IBM-MAIN subscribe / signoff / archive access instruct
Ed,
Try it. no special authority is needed to use this service. All other racf
interfaces, including irrxutil are protected by racf profile and scope.
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
Have a look at getpwent. If I am not allowing a user to list RACF users,
why are they allowed to list it via this command using syscalls?
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
Thanks John,
My concern is access to other syscall functions. it may be true to unix,
but I think some of them allow more information then I would allow to
standard user.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security
a user asks to have access to the uss sleep syscall. We would like to limit
the user only to this function. is this possible?
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming
--
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
--
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring f
or IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
--
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
-
All racf violations are reported by SMF80, regardless of the environment of
execution.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz
I just know I am, but if I know the answer to this
> already I can't dredge it up. I want to list all the datasets on a
> particular DASD volume. I'd use LISTCAT LVL('hlq'), but these are not
> catalogued. Where's the TSO command for that?
>
> --
> For IBM-MAIN subscribe / sign
It happens to me with other emulators as well when the data
contains unprintable character. It might be the reason.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Tue, Mar 30, 2021 a
Do you have an ip address? Who own it?
בתאריך יום ו׳, 12 במרץ 2021, 15:32, מאת Stan Saraczewski <
stansaraczew...@gmail.com>:
> The host where my client has rented time and stored software is now
> unreachable. Used to get a standard VTAM large logo proclaiming MTI-1 and a
> list of apps below,
BMC Control-J? (but you need to have Control-M I believe.
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Thu, Mar 11, 2021 at 9:30 PM Charles Mills wrote:
> ASG has one. JCL-Prep?
>
John,
Someone is worried about your retirement and will extend the number of
tries until then ;-)
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz
Model9
בתאריך יום ה׳, 4 במרץ 2021, 19:35, מאת Bodra - Pessoal <
02eda2bc565a-dmarc-requ...@listserv.ua.edu>:
> 1. IBM TS7700
> Real tapes only as VTS backend -
>
> TS7760 has option to do not destage data to real tapes. All data stay in
> VTS (as other vendors does).
>
> 2. STK/Sun/Oracle
The issue here is fallback. Not production run.
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
*Skype
John,
I read the doc. It describes ACF2 coverage for UADS functionality. But what
happens if ACF2 refuses to start? In RACF, the UADS dataset is saved in
RCVTUADS. I looked at ACCVT mapping macro and there is no such field.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software
UADS is in a bypass state. However, I still wonder what happens if ACF2
fails to start and we need to authenticate with UADS. Where is the UADS
dataset name saved? I don't think we can access the MSTRJCL data area (I
don;r think it is documented anywhere).
*| **Itschak Mugzach | Director
I looked at RCVT in an ACF2 system, but the RCVTUADS is nullified. How can
I locate the active UADS in this case?
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming
looks like an ebcdic-ascii conversion issue.
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Sat, Feb 27, 2021 at 10:46 PM Lionel B Dyck wrote:
> I've got z/OS Git working on at least 5 oth
looks like an ebcdic-ascii conversion issue
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
*Skype
Nice story. However I think the discussion is limited to IT status auditing.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Tue, Feb 23, 2021 at 6:49 PM Bill Johnson <
00475
it is configed.
As lizette says, if you have not already done that (now, my suffix) by an
audit product. There are some in the market, and let them collect the
information themselves.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous
zMan,
The "mainfame" is just to remind us that some people think that "sic
transit gloria mundi" of the mainframe...
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On
On Thu, 4 Feb 2021 16:17:59 +0200 ITschak Mugzach
> > wrote:
> >
> > :>the DB2-L group seems to be inactive, so i am asking here...
> >
> > :>I have a rexx program that calls stored procedures and gets -805. the
> > :>complete details below. I followed t
the bind of DSNREXX severa times.
SQLCODE=-805
SQLERRMC=DALLASC..DSNREXX.0E4C9F4F04F3F1F2.DSNREXX.03
SQLERRP =DSNXEPM
SQLSTATE=51002
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming
COND(ence) allows you to have the source code embedded in the executable
with all goodis that comes with it, without making the code visible.
NOTRACE, will disable traces (incase the user hits attention).
My two cents (Israeli Shekel)
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software
see BPX related health checks.
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
*Skype**: ItschakMugzach
Started tasks are started by a console command START (S ). There
are more variations to the command, but this is the basic one. If you want
the same task run in parallel with the same tak, add a name (S .yyy).
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information
Tx Charles.
I tested that there already. My rexx returns a different time. I noticed
that they only use the first four bytes. The code snip I gave is from the
TOD IPCS rexx.
Anyway, it will be an assembler, but I still wonder why I get wrong
numbers.
ITschak
*| **Itschak Mugzach | Director
- XXX - RETVAL
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
*Skype**: ItschakMugzach **|* *Web
True, but the difference may be within 24 hours. I get 21 days late
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522
Paul,
So if I ignore leap seconds, Can I just divide the number by 409600 and
subtruct 1.1.1970-1.1.1900?
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz
it,
but I want to keep the correct epoch time.
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
--
For IBM-MAIN subscribe / signoff / arc
If the question relates to CICS, you can use the VERIFY PASSWORD exec
interface call.
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il
No. The interpreter already read the jcl at translation time.
בתאריך יום ג׳, 22 בדצמ׳ 2020, 19:11, מאת Fred Kaptein <
fred.kapt...@telus.com>:
> Hello,
> I would like to build a JCL batch job called BACKUPS, that does the
> following:
> 1) STEP01
> Create a JCL proc in MYLIB.PROCLIB(BKUP)
>
ou
> want timeout then specify PWT(SMF). Note that this will have consequences
> for some USS apps so it may not be an appropriate change for some systems,
> particularly production.
>
> On Thu, Dec 10, 2020 at 8:39 PM ITschak Mugzach
> wrote:
>
> > I noticed
I noticed that if I start OMVS, my TSO account is not disconnected after
the time limit. It will remain active until the next IPL. I tested that in
various OS levels and few clients (including our lpars).
Any idea why?
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security
See SYS1.PARMLIB(AUTORxx)
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM coming soon *
On Mon, Nov 30, 2020 at 10:39 AM Itschak Mugzach
wrote:
> See SYS1.PARMLIB(AUTORxx)
>
> *| **Itschak Mugza
See SYS1.PARMLIB(AUTORxx)
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
*Skype**: ItschakMugzach
true: jes parm dupl_job=nodelay, but the op asked about STCs.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522
STCs can be started with a unique name (S xxx.yyy where yyy make it
unique). However, the TSC itself can block coincarency by enquing a
resource exclusively. so the answer is yes, but depends on the STC.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform
Mike,
ACBGEN only requires MODIFY PREPARE ACBLIB. follow the messages on syslog.
Program status NOTINIT means that the program resources (such as PSB, DBD,
ACB, etc.) are not available.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information
Looked at my IMS 15 product libraries and found no such module. Does it
have the fmid inside? Why do you think it is IMS?
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Tue, Oct 27,
Try ieasynck from sys1.samplib
ITschak
בתאריך יום ב׳, 5 באוק׳ 2020, 7:53, מאת Brian Westerman <
brian_wester...@syzygyinc.com>:
> I don't have a sysparm member in sys1.samplib, is it from an older release
> than 2.3?
>
> Brian
>
> On Sun, 4 Oct 2020 16:48:25 +, Jesse 1 Robinson <
>
Same IPL address, same IPL parms as before?
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
*Skype
TSO information is kept is the user's TSO segment OF the ESM (TACF, TSS,
etc.) in use.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Wed, Sep 23, 2020 at 2:26 PM Attila Fogarasi w
TSO information is kept is the user's TSO segment OF the ESM (TACF, TSS,
etc.) in use.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz
You better ask here. I am registered to the IMS group but haven't got any
email for a long time now.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Tue, Sep 22, 2020 at 6:51 PM Its
The command is used to load modules into the Dynamic LPA that resies in
(e)csa.
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob
i, 18 Sep, 2020, 5:56 pm Peter, wrote:
>
> > We have a MLPA module from adabas which got loaded But we aren't able to
> > trace from which dataset it was loaded.
> >
> > Is there a way to know the dataset name from which or where it is saved ?
> >
&
Peter,
There are some 3rd party products that load modules to modified LPA (CSA or
ECSA) as they start. They do it dynamically so if they don't start, you
save the storage.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security
Yes.
בתאריך יום ו׳, 18 בספט׳ 2020, 8:58, מאת Peter :
> IEALPAxx and LPALSTxx treated in same way ?
>
>
>
>
> On Fri, 18 Sep, 2020, 9:44 am Seymour J Metz, wrote:
>
> > You can search an LPA module with IPCS.
> >
> > In addition to the SETPROG command there's the CSVDYLPA macro.
> >
> >
> > --
Peter,
To load into dynamic lpa use setprog,add,modname=
To test if already loaded use d prog,lpa,modname=
There are macro calls for both if you want to do that from a program.
ITschak
בתאריך יום ו׳, 18 בספט׳ 2020, 6:43, מאת Peter :
> Hello
>
> Is there any utility which can help to
PF setting is ispf application sensitive. Try keys at the command line
while in edit. What us the value of "pf21"?
בתאריך יום ב׳, 24 באוג׳ 2020, 19:58, מאת Bob Bridges :
> This is a really weird one. My key is not getting any
> response from ISPF, and before you tell me it must be my keyboard
AXR Stop command introduced in z/os 2.2.
בתאריך יום ו׳, 21 באוג׳ 2020, 11:13, מאת Mike Shorkend <
mike.shork...@gmail.com>:
> STOP AXR or P AXR to stop system rexx, only came around in z/OS 2.4. Anyone
> not yet there will have to use the force command.
>
> On Fri, 21 Aug 2020
Axr will shut down by a stop command. No violence needed -)
בתאריך יום ו׳, 21 באוג׳ 2020, 6:48, מאת Barbara Nitz :
> >Systemrexx is started automatically during IPL. What are you trying to
> get?
>
> Not sure about the OP, but I would like to start it sub=mstr, too, just so
> it doesn't screw
Systemrexx is started automatically during IPL. What are you trying to get?
ITschak
בתאריך יום ה׳, 20 באוג׳ 2020, 22:33, מאת Lionel B Dyck :
> And if so where would that be changed as I can't find where it is started
> now?
>
>
>
> Thanks in advance.
>
>
>
>
>
> Lionel B. Dyck <
> Website:
Systemrexx is started automatically during IPL. What are the advantage of
running systemrexx under the mstr subsys?
ITs hak
בתאריך יום ה׳, 20 באוג׳ 2020, 22:33, מאת Lionel B Dyck :
> And if so where would that be changed as I can't find where it is started
> now?
>
>
>
> Thanks in advance.
>
>
.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Wed, Aug 19, 2020 at 10:00 PM Lizette Koehler
wrote:
> List -
>
>
>
> I have been researching whether we need to review
Or not. If you find the fmid ptf, it is. if not, try the other one.
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Wed, Aug 19, 2020 at 5:49 PM Jeremy Nicoll
wrote:
> On Wed, 19 Aug 2020
Or not. If you find the fmid ptf, it is. if not, try the other one.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob
or just browse one of the PTFs and see the FMID. Than use the SMPE ISPF
interface option 3.2 (Cross Zone Query) to see if the FMID is installed...
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS
Opps. Forgot the sigl...
בתאריך שבת, 15 באוג׳ 2020, 0:31, מאת Paul Gilmartin <
000433f07816-dmarc-requ...@listserv.ua.edu>:
> On Fri, 14 Aug 2020 23:45:19 +0300, ITschak Mugzach wrote:
>
> >I once wrote an installer that behaved like a zip exec. I think it was
> &g
number of )ATTR */
/* READ PANEL FROM INSTREAM DATA */
.
Ens
Return
DataStack:
StackStart = SourceLine() /* get this line number */
Return
)ATTR DEFAULT(...)
)BODY
)INIT
)PROC
)END
EOF
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous
eputation. Character is what
> you are, reputation merely what others think you are." - John Wooden
>
> -Original Message-
> From: IBM Mainframe Discussion List On Behalf
> Of ITschak Mugzach
> Sent: Tuesday, August 11, 2020 10:21 AM
> To: IBM-MAIN@LISTSE
This is simply because the record is written to syslog starting at column
58 and the syslog record length is 131.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Tue, Aug 11, 2020 at
Walt,
The user need access to query racf with IRRXUTIL as well. I think the best
way is a racroute 3rd party check, and a the rexx ned to be compiled to
hide the code.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous
Have a look at MODEL9. I know some clients of us that are using it to
backup to the cloud.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Wed, Aug 5, 2020 at 5:54 PM R.S. wrote:
>
What change does it make? IBM does ot recommend parsing of command output
as it keeps the right to change output format.
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Sun, Aug 2, 2020 at 2:4
ation merely what others think you are." - John Wooden
>
> -Original Message-----
> From: IBM Mainframe Discussion List On Behalf
> Of Itschak Mugzach
> Sent: Sunday, August 2, 2020 6:29 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Re: Query ESM from REXX
>
> -)
>
> בתאריך
-)
בתאריך יום א׳, 2 באוג׳ 2020, 14:27, מאת David Spiegel <
dspiegel...@hotmail.com>:
> Shkoyach
>
> On 2020-08-02 07:25, Itschak Mugzach wrote:
> > You need to use this or wright an assembler program to execute a third
> > party check on the resource in question. E
ll you if a user has access to a resource.
>
> -Original Message-
> From: IBM Mainframe Discussion List On Behalf
> Of Itschak Mugzach
> Sent: Sunday, August 2, 2020 2:16 PM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Re: Query ESM from REXX
>
> Look at IRRXUTIL
>
Look at IRRXUTIL
ITschak
בתאריך יום א׳, 2 באוג׳ 2020, 14:06, מאת Gadi Ben-Avi :
> Hi,
> Does anyone know of a way to query an ESM (RACF in this case) from a REXX
> program running under TSO/E and ISPF?
> We are currently at z/OS v2.2.
>
> I would like to know if a user has a certain access
of DASD formatting software). It can
also be caused by link-editing a module. When a new extent is allocated,
you can access the modification only by first terminating and then invoking
ISPF again.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform
PDF is an alias of ISPF. you can use ISPF TEST just to load ISPF again.
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972
Gadi,
During development, once you logged-on, exit ISPF to TSO and enter PFG
TEST. the TEST operand will cause ISPF to read the panel definition from
the dataset every time you reference it.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform
ny
> Electric Dragon Team Paddler
> SHARE MVS Program Co-Manager
> 323-715-0595 Mobile
> 626-543-6132 Office ⇐=== NEW
> robin...@sce.com
>
> -Original Message-
> From: IBM Mainframe Discussion List On Behalf
> Of Itschak Mugzach
> Sent: Monday, July 27, 2020 2:03 PM
&
CICS does not require a CICS segment, so if you do not block the user at
the APPL, the default user CICS segment inherented to the user. Still don't
understand why the helpdesk users password authentication fails if it works
under TSO.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam
what does it look like after copying from USS to PDS?
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **| *
*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404
How about appl class? If the user is not authorized to the cics applid, he
can't login.
Btw, why (and how) is their password different on cics? If racf recognize
they have the special attribute, it seems this is the same racf...
ITschak
ITschak Mugzach
*|** IronSphere Platform
How about appl class? If the user is not authorized to the cics applid, he
can't login.
Btw, why (and how) is their password different on cics? If racf recognize
they have the special attribute, it seems this is the same racf...
ITschak
בתאריך יום ב׳, 27 ביולי 2020, 23:40, מאת Lizette Koehler
Lionel,
Do you want to display the exact copy of the ISPF display in HTML? is this
what you are looking at (Without the logic parts as )INIT, )REINIT, PROC,
etc.)?
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous
Rex,
I think the emulation of Z is only one step. the next step is moving to
modern languages as you go.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Thu, Jul 16, 2020 at 12:1
Still, is it a one to one application? I mean, user logon to his own TSO
account? BTW, if you do not need SSL, you don't need to use the web
enablement. it is more complex to use. simple rexx TCPIP support is
sufficient.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software
The problem was solved years ago outside of the mainframe. I am sure there
are vendor reps here to tell.
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
for z/OS, x/Linux & IBM I **| z/VM comming son *
On Thu, Jul 16, 2020 at 10:52 AM D
There was such application (except the logon issue) part of ispf but i
think it was deprecated (tx god, it was very unsecure).
Is it a one region for one user application? If so, you do not need to
manage sessions like a web server, just a simple listener in rexx. There is
a French product that
A simpler way is to write the protocol yourself. It requires zero
configuration other than a set of certificates. Have a look at z/os web
enablement toolkit (Http/https protocol enabler portion). Works great and
fully supports Rexx.
ITschak
*| **Itschak Mugzach | Director | SecuriTeam Software
Lionel,
OMVS has many options, ope of them is scroll/noscrolk. But why not redirect
output to a file? This way you don't need to see or scroll the list and can
later review errors.
ITschak
בתאריך שבת, 27 ביוני 2020, 19:05, מאת Lionel B Dyck :
> Tried the background option you suggested and
OK. Ent. Cobol 4.x and forward. The program may run under CICS or batch. I
would like to use a standard, RACF stored certificate for this instead of
CSNDDSG which uses a private key from ICSF.
Tx,
ITschak
ITschak Mugzach
*|** IronSphere Platform* *|* *Information Security Continuous Monitoring
I know i can digitally sign with icsf. However, the requirement is to use s
certificate and private key.
Possible?
ITscchak
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
301 - 400 of 1002 matches