Re: File 228 CBT tape - HSM panel recovery

2019-05-18 Thread Peter
Thanks Peter and Mike On Sun, 19 May, 2019, 8:54 AM Mike Schwab, wrote: > http://www.cbttape.org/updates.htm > > > On Sun, May 19, 2019 at 4:31 AM Peter wrote: > > > > Hi Peter > > > > > > I still don't find the updated 228 file in CBTTAPE. > > > > Could you please send me offline if you

Re: File 228 CBT tape - HSM panel recovery

2019-05-18 Thread Mike Schwab
http://www.cbttape.org/updates.htm On Sun, May 19, 2019 at 4:31 AM Peter wrote: > > Hi Peter > > > I still don't find the updated 228 file in CBTTAPE. > > Could you please send me offline if you have now ? > > Peter > > On Fri, 17 May, 2019, 7:18 PM Peter Vander Woude, > wrote: > > > I just

Re: File 228 CBT tape - HSM panel recovery

2019-05-18 Thread Peter
Hi Peter I still don't find the updated 228 file in CBTTAPE. Could you please send me offline if you have now ? Peter On Fri, 17 May, 2019, 7:18 PM Peter Vander Woude, wrote: > I just submitted to the cbt site, an updated file 228, that works > correctly. > > The problem lies in how the

Re: File 228 CBT tape - HSM panel recovery

2019-05-17 Thread Peter Vander Woude
I just submitted to the cbt site, an updated file 228, that works correctly. The problem lies in how the clist was parsing the output from the hsm command. The format changed a long time ago. I had got it working for me, just didn't think about submitting the changes. Peter

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Peter Glanzmann
Hi again Take a look to the following code section in File 228 and change the SUBSTR and the "BACKUP" to the HLQ matching your names. /* LOOK FOR BEGINNING OF BCDS SECTION */ IF (31:36,) =

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Allan Staller
Thanks Mark. I never could find that info in the FM's -Original Message- From: IBM Mainframe Discussion List On Behalf Of Mark Jacobs Sent: Thursday, May 16, 2019 7:27 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: File 228 CBT tape - HSM panel recovery HELP HLIST says that HSM

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Mike Schwab
5:41 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: File 228 CBT tape - HSM panel recovery > > No the BCDS is not hard coded it's basically doing a HLIST and writing to > ODS. unfortunately the output file is not read properly to display the HSM > backup > > On Thu,

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Mark Jacobs
AIN@LISTSERV.UA.EDU > Subject: Re: File 228 CBT tape - HSM panel recovery > > No the BCDS is not hard coded it's basically doing a HLIST and writing to > ODS. unfortunately the output file is not read properly to display the HSM > backup > > On Thu, 16 May, 2019, 2:29 PM Peter

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Allan Staller
Discussion List On Behalf Of Peter Sent: Thursday, May 16, 2019 5:41 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: File 228 CBT tape - HSM panel recovery No the BCDS is not hard coded it's basically doing a HLIST and writing to ODS. unfortunately the output file is not read properly to display

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Mike Schwab
I wrote a program to anaylize a IDCAMS output. Every few years the size of some fields would increase and the report literals would be moved to allow the larger fields. I would check these positions in the analysis program. Better would be to look at an IDCAMS DCOLLECT filed because those

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Peter
No the BCDS is not hard coded it's basically doing a HLIST and writing to ODS. unfortunately the output file is not read properly to display the HSM backup On Thu, 16 May, 2019, 2:29 PM Peter Glanzmann, wrote: > Hi Peter > > I assume that the source code of the program in CBT file 228 has the

Re: File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Peter Glanzmann
Hi Peter I assume that the source code of the program in CBT file 228 has the name of the BCDS hard coded. Please search for the BCDS name in the CLIST and replace it using the one of your installation. Best regards Peter --

File 228 CBT tape - HSM panel recovery

2019-05-16 Thread Peter
Hi I am trying to use this file for a panel based recovery of HSM managed backup . When I do HLIST DSN('XXX.YY.ZZ') BCDS I get the details of backup but when I use the CBTTAPE 228 it doesn't show up anything ? Is anyone using it and getting as expected ? Peter