Re: [Powernet] Neutron dose tracking

2018-04-16 Thread Bob Simmons via Powernet
North Anna- 1.)Primarily SRD's however we will back that up with stay times and a REM ball in case we get an anomaly with the SRD which has happened. 2.)No specific criteria other than what's stated above. 3.)No 4.)Yes we have an AmBe source and we track exposure when using

Re: [Powernet] Neutron dose tracking

2018-04-16 Thread Holmes, Stephen J:(GenCo-Nuc) via Powernet
1. Primarily neutron SRDs 2. If area hasn't been characterized for neutron SRD energy response, preferred technique is timekeeping with REM500 3. No 4. Yes. We have one neutron source and we require neutron dosimetry and neutron surveys when working with this source 5. Only

[Powernet] Neutron dose tracking

2018-04-16 Thread Beth Heyeck via Powernet
We are looking at streamlining our neutron dose tracking and are wondering how other plants are performing it. 1. Which do you use for determining neutron dose for workers in Neutron Exposure Areas: a. Stay time tracking b. Gamma to neutron ratios c. Neutron sensitive

Re: [Powernet] Ludlum 9DP and 9DP* Pressurized Ion Chamber

2018-04-16 Thread Macho, Michael via Powernet
CPNPP doesn’t use the 9DP. We use the Ludlum R9-7 Michael Macho Radiation Protection Staff michael.ma...@luminant.com [cid:image002.jpg@01D3D559.1A746E40] SAFETY is first QUALITY SCHEDULE Luminant Power Comanche Peak Nuclear Power Plant 6322 North FM 56 or PO Box 1002 Mail Code 005A Glen Rose,